[ISS Support Case] RDI Tags Failing to Update or become stuck in initializing status

Last updated: October 17th, 2025

Description

Specific tags located under one PLC are not auto updating with communication data. The quality is showing as good, but these tags seem to only update throughout the system when the graphic where the object is linked to the tag is opened. Otherwise the values do not seem to update. This is an issue because there are Batch process's that depend on the information contained within these tags to initialize the Batch. I tried having the client set the scan group in the DDESuitlink object for these tags to ActiveAll and redeploy, but this does not seem to have had any effect. I also did notice the clients system is under resourced in regards to the logical cores by about 4-6 cores. They are going to address this in a down window. They may be able to do this at 2 pm EST today so I am looking for a meeting at that time if possible to work on diagnosing the issue should the additional system resources not rectify the issue.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: DA OI Servers
Version: 2023
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 07/03/2025
Case: 88511
Give feedback about this article

Recommended articles

[ISS Support Case] TI 500 - Disconnected Post CDP 2023 R2 P01

Upgraded to 2023 R2 P01 experienced a disconnect at 8am this morning. Describes loaded log file. Seems like this happened once before shrugged it off Firmware 1.27 South parkway WWTP

Read More

[ISS Support Case] OI Gateway Servers disconnecting every 7 minutes

They stay offline for about 2 minutes then they reconnect. They don't see any reconnect scripts that could cause it. They are waiting to reboot until they have a good opportunity. System platform 2020R2 SP1 They recently migrated to a new server. Suggested it may be a firewall or security program interfering with the connection. They will check with the IT department about that. Not available until the afternoon on 9/6/2024

Read More

[ISS Support Case] Professional license required

Were creating a new instance of the OI server the error, professional license required as displayed

Read More

[ISS Support Case] Failure to Create Additional MBTCP Server Instance

Client reached out as when user was attempting to create additional MBTCP server instance they received the following error message: "Multi-Instance configuration is only supported with a professional level license or higher. Please upgrade the license to create additional instance's." Client also had the following error in the logger: "LicAPISvcProxy.NET failed to communicate with Aveva Enterprise License product service."

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand