[ISS Support Case] RDI Tags Failing to Update or become stuck in initializing status
Last updated: October 17th, 2025Description
Specific tags located under one PLC are not auto updating with communication data. The quality is showing as good, but these tags seem to only update throughout the system when the graphic where the object is linked to the tag is opened. Otherwise the values do not seem to update. This is an issue because there are Batch process's that depend on the information contained within these tags to initialize the Batch. I tried having the client set the scan group in the DDESuitlink object for these tags to ActiveAll and redeploy, but this does not seem to have had any effect. I also did notice the clients system is under resourced in regards to the logical cores by about 4-6 cores. They are going to address this in a down window. They may be able to do this at 2 pm EST today so I am looking for a meeting at that time if possible to work on diagnosing the issue should the additional system resources not rectify the issue.
- Author: Kevin Modlin
- Published: October 17th, 2025
Details:
Product: DA OI Servers |
Version: 2023 |
Solution: [Solution is visible below when you're logged in and have a current subscription] |
Date Created: | 07/03/2025 |
Case: | 88511 |
Recommended articles
[ISS Support Case] TI 500 - Disconnected Post CDP 2023 R2 P01
Upgraded to 2023 R2 P01 experienced a disconnect at 8am this morning. Describes loaded log file. Seems like this happened once before shrugged it off Firmware 1.27 South parkway WWTP
Read More[ISS Support Case] OI Gateway Servers disconnecting every 7 minutes
They stay offline for about 2 minutes then they reconnect. They don't see any reconnect scripts that could cause it. They are waiting to reboot until they have a good opportunity. System platform 2020R2 SP1 They recently migrated to a new server. Suggested it may be a firewall or security program interfering with the connection. They will check with the IT department about that. Not available until the afternoon on 9/6/2024
Read More[ISS Support Case] Professional license required
Were creating a new instance of the OI server the error, professional license required as displayed
Read More[ISS Support Case] Failure to Create Additional MBTCP Server Instance
Client reached out as when user was attempting to create additional MBTCP server instance they received the following error message: "Multi-Instance configuration is only supported with a professional level license or higher. Please upgrade the license to create additional instance's." Client also had the following error in the logger: "LicAPISvcProxy.NET failed to communicate with Aveva Enterprise License product service."
Read More