Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Communication Drivers
  • AVEVA Communication Drivers Support Cases

[ISS Support Case] OI Gateway Servers disconnecting every 7 minutes

Last updated: March 6th, 2025

Description

They stay offline for about 2 minutes then they reconnect. They don't see any reconnect scripts that could cause it. They are waiting to reboot until they have a good opportunity. System platform 2020R2 SP1 They recently migrated to a new server. Suggested it may be a firewall or security program interfering with the connection. They will check with the IT department about that. Not available until the afternoon on 9/6/2024

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: DA / OI Servers
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 09/23/2024
Case: 87758
Give feedback about this article

Recommended articles

[ISS Support Case] TI 500 - Disconnected Post CDP 2023 R2 P01

Upgraded to 2023 R2 P01 experienced a disconnect at 8am this morning. Describes loaded log file. Seems like this happened once before shrugged it off Firmware 1.27 South parkway WWTP

Read More

[ISS Support Case] Professional license required

Were creating a new instance of the OI server the error, professional license required as displayed

Read More

[ISS Support Case] Failure to Create Additional MBTCP Server Instance

Client reached out as when user was attempting to create additional MBTCP server instance they received the following error message: "Multi-Instance configuration is only supported with a professional level license or higher. Please upgrade the license to create additional instance's." Client also had the following error in the logger: "LicAPISvcProxy.NET failed to communicate with Aveva Enterprise License product service."

Read More

[ISS Support Case] Setting up communication to a CompactLogix 5380 PLC

I have an HMI application in Intouch 2020 R2 SP1 20.1 and I should configure the communication via AVEVA ABCIP driver with the Rockwell Allen Bradley PLC CompactLogix 5380. Can you give me some instructions how that has to be done? Is there any document or site that explains that?

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand