[ISS Support Case] Insight Solution Stopped Publishing

Last updated: October 17th, 2025

Description

have an aveva insight application that used to work (till about 20 days ago). It routes data from OPC and publishes it for access via insight. I'm not an expert at these systems. The OCMC in the help about says it's version 2022.0713.4211.1. I tried repairing the installation with the old install file --> No improvements. I tried installing with the current download from online.wonderware.com. In the OCMC, I see the data that is collected from the OPC server refresh. --> I think the OCMC is collecting the data. The Log file shows a couple errors I cannot figure out: including: Publisher failed to configure store/forward 'C:\ProgramData\ArchestrA\Historian\IDAS\SF\LOCALHOST\' for LOCALHOST, error = 138 (Failed to write to Store/Forward lock file) [CIMSERVER; StorageNode.cpp; 1238] Publisher failed to restart acquisition, error = 138 (Failed to write to Store/Forward lock file) [CIMSERVER; IdasServer.cpp; 3095] I have tried deactivating the OI.Gateway. and stopping the wonderware suitelink. Then resume the gateway and restart the process. I have tried to attached the log file with the last few hours of entry. the system rejected the log file so I changed the extension from *.aaLGX to *.txt

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Comm Drivers
Version: 2023
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 09/19/2022
Case: 82556
Give feedback about this article

Recommended articles

[ISS Support Case] TI 500 - Disconnected Post CDP 2023 R2 P01

Upgraded to 2023 R2 P01 experienced a disconnect at 8am this morning. Describes loaded log file. Seems like this happened once before shrugged it off Firmware 1.27 South parkway WWTP

Read More

[ISS Support Case] OI Gateway Servers disconnecting every 7 minutes

They stay offline for about 2 minutes then they reconnect. They don't see any reconnect scripts that could cause it. They are waiting to reboot until they have a good opportunity. System platform 2020R2 SP1 They recently migrated to a new server. Suggested it may be a firewall or security program interfering with the connection. They will check with the IT department about that. Not available until the afternoon on 9/6/2024

Read More

[ISS Support Case] Professional license required

Were creating a new instance of the OI server the error, professional license required as displayed

Read More

[ISS Support Case] Failure to Create Additional MBTCP Server Instance

Client reached out as when user was attempting to create additional MBTCP server instance they received the following error message: "Multi-Instance configuration is only supported with a professional level license or higher. Please upgrade the license to create additional instance's." Client also had the following error in the logger: "LicAPISvcProxy.NET failed to communicate with Aveva Enterprise License product service."

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand