[ISS Support Case] Downgrading - Uninstall Reinstall Guidance

Last updated: March 7th, 2025

Description

Some time ago you provided us with a tech note regarding downgrading the CDP 2023 R2 back to CDP 2023 when installed on a common single host with System Platform 2023 R2 installed. REF CASE 88042 Since then, we are considering our options with a potential upgrade to System Platform 2023 R2 SP1. Ideally, we would prefer to do this with the supplied CDP 2023 R2 SP1 version, as this supports the latest .NET 8.0 from a security perspective. However, due to legacy PLC firmware in the field, we wish to know if the downgrade method we used previously is still possible with R2 SP1.

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: Communication Drivers
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 02/27/2025
Case: 88857
Give feedback about this article

Recommended articles

[ISS Support Case] TI 500 - Disconnected Post CDP 2023 R2 P01

Upgraded to 2023 R2 P01 experienced a disconnect at 8am this morning. Describes loaded log file. Seems like this happened once before shrugged it off Firmware 1.27 South parkway WWTP

Read More

[ISS Support Case] OI Gateway Servers disconnecting every 7 minutes

They stay offline for about 2 minutes then they reconnect. They don't see any reconnect scripts that could cause it. They are waiting to reboot until they have a good opportunity. System platform 2020R2 SP1 They recently migrated to a new server. Suggested it may be a firewall or security program interfering with the connection. They will check with the IT department about that. Not available until the afternoon on 9/6/2024

Read More

[ISS Support Case] Professional license required

Were creating a new instance of the OI server the error, professional license required as displayed

Read More

[ISS Support Case] Failure to Create Additional MBTCP Server Instance

Client reached out as when user was attempting to create additional MBTCP server instance they received the following error message: "Multi-Instance configuration is only supported with a professional level license or higher. Please upgrade the license to create additional instance's." Client also had the following error in the logger: "LicAPISvcProxy.NET failed to communicate with Aveva Enterprise License product service."

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand