TN 1136 Backing Up Your j5 Server

Last updated: March 5th, 2025

Description

  • Author: Ron Tanner
  • Published: March 5th, 2025

Details:

Description

Backing Up Your j5 Server

  • Author: Ron Tanner
  • Published: 03/31/2021
  • Applies to: j5 2019

Details

  1. j5 Database - must be backed up regularly and must be replicated to the failover system. You can use 3rd party applications for the backup or use the Database client tools such as SQL Server Management Studio depending on the database you use for j5.
  2. Data Files - must be backed up regularly and should be replicated to the failover system.
    1. File Attachments. The location of the attachments is a configuration option in the j5 System Management Console - File System Storage
    2. C:\ProgramData\j5\data (exclude C:\ProgramData\j5\data\solr - this is an index and will be rebuilt after failover to ensure data consistency)
  3. Local Settings - should not be replicated to the failover system but should be backed up to a separate location
    1. C:\ProgramData\j5\confi
    2. C:\ProgramData\j5\generated_files
    3. C:\ProgramData\j5\licenses
  4. Log Files - should not be replicated to the failover system but should be backed up to a separate location
    1. C:\ProgramData\j5\log
  5. Temporary Files - should not be replicated to the failover system
    1. C:\ProgramData\j5\cacheC:\ProgramData\j5\pid
    2. C:\ProgramData\j5\temp
    3. C:\ProgramData\j5\data\sol
  6. Installed Application Files - should not be replicated to the failover system.
    1. C:\Program Files (x86)\j5
server backup j5
Give feedback about this article

Recommended articles

TN IT166 How to create a sound for an alarm in InTouch

Read More

TN IT170 Configuration issue with Alarm Hot Backup Pair.

Read More

TN IT198 Automatic logout (Inactivity Warning and Timeout)

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand