TN OI-107 Upgrading SIDIRECT from DA to OI Server

Last updated: March 19th, 2025

Description

  • Author: Rich Brooks
  • Published: March 19th, 2025

Details:

Description

This article from InSource shows how to upgrade a configuration file built for the Wonderware DA Server to be used with the OI Server for SIDIRECT. Reference the software documentation for details on the communication driver installation. This tech note describes the changes required for the configuration file only.

  • Author: Rich Brooks
  • Published: 11/11/2019
  • Applies to: OI Server for SIDirect v5.0 and higher

Details

The configuration file for SIDIRECT has changed slightly with the latest generation OI Server. Instructions are provided below to modify the dassidirect.aacfg configuration file. The configuration file for the DA Server is found in the following folder:

C:\ProgramData\Wonderware\DAServer\DASSIDIRECT

Open the XML format configuration file in Notepad. The following is an example configuration with a single PLC.

The hightlighted text "S7Cp" text above needs to be updated with the word "Legacy".

The default OI Server configuration for SIDIRECT is shown above. It provides the options of Legacy or Symbolic under the PORT. Either Legacy using address based or Symbolic using tag based references may be used. The required option needs to be specified in the configuration file. 

The following configuration file is corrected for the SIDIRECT OI Server.

In this example the tags are the Legacy address based references. Replace each reference to "S7Cp" with the word "Legacy" for configuration files with more than one PLC. A find and replace may be used to assist with the changes. The configuration file is located in the following folder.

C:\ProgramData\Wonderware\OI-Server\$Operations Integration Supervisory Servers$\OI.SIDIR\OI.SIDIR

upgrade server
Give feedback about this article

Recommended articles

Connecting to RSLinx with FSGateway

Read More

DAServer is missing in the DAServer Manager after installation or changing account password.

Read More

How to monitor a PLC Connection from Kepserver using Wonderware Intouch

Read More

TN DA101 FSGateway: Failed to create OPCEnum error

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand