TN DA126 Unable to Add Item

Last updated: March 6th, 2025

Description

  • Author: Brian Schneider
  • Published: March 6th, 2025

Details:

Description

The messages that say "Unable to add item _____" are typically caused by attempting to reference a bad PLC address. The typical solution is to go through your InTouch application (Or App Server Objects, etc.) and find the invalid reference and correct it. Sometimes there are too many applications to look through, or you simply do not have the time to look through all of them.

  • Author: Dillon Perera
  • Published: 09/11/2015
  • Applies to: DA Servers

Details

The following is a workaround to solve the issue, it should not be considered "best practice".

  1. Open the Wonderware System Management Console (Start > Programs > Wonderware > System Management Console), on the PC where the DA Server is running.
  2. Expand the DA Server Manager, and under Configuration find the branch for the problem PLC.
  3. On the tabs, select the tab called "Device Items". This tab is intended to be used for creating aliases for tags.
  4. Add a new line:
    1. Name: Enter the incorrect address that is referenced in the logger message.
    2. Item Reference: Enter the correct address which exists in the PLC.
  5. Save the changes, then restart the DA Server.

By doing this, and pointing the bad address at a valid one, the DA Server will redirect any requests for the bad address, and the logger will no longer display errors.

error item
Give feedback about this article

Recommended articles

Connecting to RSLinx with FSGateway

Read More

DAServer is missing in the DAServer Manager after installation or changing account password.

Read More

How to monitor a PLC Connection from Kepserver using Wonderware Intouch

Read More

TN DA101 FSGateway: Failed to create OPCEnum error

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand