TN 1283 Troubleshooting Deployment_Failures

Last updated: February 26th, 2025

Description

  • Author: Brian Schneider
  • Published: February 26th, 2025

Details:

Description

  • Author: Mario Meza
  • Published: 09/16/2022
  • Applies to: Application Server 2017 and above

Details

  1. Run Change Network Account Utility “Run as Administrator” (even if you are an Administrator)
    1. C:\Program Files (x86)\Common Files\ArchestrA\aaAdminUser.exe   
  2. Run OSConfig Utility “Run as Administrator” (even if you are an Administrator)
    1. C:\Program Files (x86)\Common Files\ArchestrA\OSConfigurationUtility.exe   
  3. Validate Binding Order / Interface Metric of the primary NIC (TN WW202)
  4. Relax System Management Server if possible or validate it is not being used   
    Make sure to run Configurator with the option “Run as Administrator” (even if you are an Administrator)   
  5. Firewall Relaxed or Exceptions in place
  6. AV Exceptions in Place
  7. From Command prompt execute ping /a for getting through to DNS and to see what the return time is
    1. A DNS reply 5 second to DNS Server is no good. Per AVEVA you want reply 4 seconds or less for good deployment
    2. Best practice is to use a host file just need to make sure it’s updated should IP’s change.
    3. You need to ping by both host name & IP (the needs to be done from both sides of the connection)   
  8. Validate Host File for accuracy (TN WW208)   
  9. Local Security Policy->Local Policies->Security Options →   
    “System cryptography: Use FIPS complaint algorithms for encryption, hashing and signing” - Disabled   
  10. Local Security Policy -> Local Policies -> Security Options ->     
                   “Network Access: Let everyone permissions apply to anonymous users - Enabled   
  11. Apply TN 000022811 Troubleshooting Wonderware Application Server Bootstrap Communications
  12. Validate NT SERVICE\aaPIM is in Administrators Group and Service Logon are correct for the ArchestrA services  
    (Ref TN 10225 New Accounts and Security Groups in Wonderware System Platform 2017 Update 3 and later )  
  13. Logged in user is part of aaAdministrators and aaConfigTools group  
  14. Ensure any Installed KB is validated against Security Central Export  (One approach is outlined Step 3 of TN 10131)  
  15. Test with a new object instance (Also applies to UDOs, Engines, Areas, Platforms etc)  
  16. Try a deploy from another galaxy or create a test Galaxy (when possible)
  17. Run a Repair of the Software (ENSURE UNBLOCKED MEDIA is USED)

NOTE: You may encounter an orphaned platform or a hung deployment while trouble shooting. This can result in a deployment conflict / mismatch.

Here are 3 options for dealing with them.

OPTION 1: Use the SMC

The preferred method to recover in these scenarios is to use the Remove Local Platform from the deployed client (NOT GR!)   

Then in the IDE you would undeploy the node that was ‘Removed’ with the option ‘On fail mark as Undeployed’ 

In some scenarios you may not see the 'remove local platform' option available in the SMC.

OPTION 2: Use the Killer / Remover Utilities

There are some utilities that remove platforms when run from the from the deployed client (DO NOT RUN ON GR!) 

Platform Remover (2016) WSP 2017 and above : https://insourcess.box.com/s/plik1oc6lgfrxbtfq0fjfv60nt82wjvt

A² Platform Killer WSP 2014 and below: https://insourcess.box.com/s/ijmjli3ddi06m0m85icbmonazvknx649

After running the appropriate utility for your version on the deployed client.

In the IDE you would undeploy the node that was ‘Removed’ with the option ‘On fail mark as Undeployed’

OPTION 3: Clean Up the Registry

Finally, there is a manual process which can be done by deleting orphaned entries from the registry.

MODIFICATIONS TO THE REGISTRY ARE DONE AT YOUR OWN RISK.

BEFORE MAKING ANY MODIFICATION ENSURE SURE YOU BACK UP AND TEST FIRST IN A SANDBOX

  1. From the IDE undeploy the orphaned / hung node with the option ‘On fail mark as Undeployed’ (This should remove the node from registry of all nodes).
  2. Go to RegEdit ->HKEY LOCAL MACHINE -> Software -> WOW6432Node -> Archestra -> Framework -> Platform -> PlatformNodes
  3. Verify that the remote node is gone from the list. If it’s not, it needs to be manually removed.

***Depending on size of galaxy this may be big task because you would have to do this on all nodes.

***Note on GR Platform0 and Platform1 should be the GR

Diagnostic Manager App

Nine times out of ten the above checklist list takes care of the issue, should it persist, the Diagnostic Manager App is a utility that (starting with 2017 U3) comes pre-installed with the product at: C:\Program Files (x86)\Common Files\ArchestrA\DiagnosticManagerApp.exe

When run, there is a tab called useful tip. Once selected you can select the current issue from a drop-down list. When 'Deploy' is selected, components and relevant flags to enable will be listed. Enable these, try a deployment, and collect the log export filtered to the time of the deployment. These will be key when submitting a ticket with InSource.

 

issues deployment
Give feedback about this article

Recommended articles

TN 1394 Error when Deploying: Remote Node's UserID/Password don't match GR Node's

Read More

TN 1366 Managing your Standalone InTouch Application in the Galaxy

Read More

TN - AppSrv - 16040702 Resolving "Open: Memory on the computer is low. New editor can't be launched."

Read More

TN 1040 No Alarms in Window Viewer

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand