TN IT141 Using SA Meters Optimal Range And Tracker

Last updated: March 19th, 2025

Description

  • Author: Brian Schneider
  • Published: March 19th, 2025

Details:

Description

This article describes how to use the Situational Awareness Library's SA_Meter object to gain some insight to an analog value by using the Optimal Range and Tracker Wizard Options. The "values" populated into the custom properties take advantage of the new data type supported by ArchestrA graphics called "History Summary". Covered in another article.

  • Author: Lewis Talley
  • Published: 07/09/2015
  • Applies to: System Platform 2014 R2

Details

Step 1 is to create the custom properties on the graphic, and make sure you select the appropriate History Statistics. For the Optimal Range Min and Max, I used the Min and Max History Statistics. For the Tracker I used the Average as shown below:

Step 2 is to turn on the options for Optimal Range and Tracker in the SA_Meter ArchestrA graphic. Once they are turned on, some new custom properties of the graphic will appear to allow you to map your custom properties to what the graphic needs to work as shown below:

The optimal range as indicated by the light gray in the runtime portion of the image can be used to quickly understand where a point is relative to its min/max (in my case). The tracker as indicated by blue in the runtime image can be used to quickly understand where a point is relative to its average (in my case). You can set the values of tracker and optimal range to any values that are meaningful in your process.

sa meters optimal range
Give feedback about this article

Recommended articles

TN 1394 Error when Deploying: Remote Node's UserID/Password don't match GR Node's

Read More

TN 1366 Managing your Standalone InTouch Application in the Galaxy

Read More

TN - AppSrv - 16040702 Resolving "Open: Memory on the computer is low. New editor can't be launched."

Read More

TN 1040 No Alarms in Window Viewer

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand