TN AppSvr295 Resolving the Entire Galaxy Being Checked Out: Unable to Open Objects

Last updated: March 3rd, 2025

Description

  • Author: Chris Cleope
  • Published: March 3rd, 2025

Details:

Description

This article from InSource Solutions shows you how to resolve the entire Application Server galaxy being checked out. The main symptom is being unable to edit all objects in the galaxy.

  • Author: Daniel London
  • Published: 08/04/2017
  • Applies to: Application Server

Details

There is a known issue where an entire galaxy can become checked out. The result is being unable to open or edit all objects. If this is the case, you will see a red check mark next to the galaxy object in Derivation view. This issue is caused by the security settings in the galaxy locking out objects. A reboot of the GR node or stopping/restarting the ArchestrA Galaxy Repository service could fix it, but if it does not the following steps are recommended.

  1. In the IDE, go to Galaxy -> Configure -> Security
  2. Under the Roles tab, change the access level value by one (ex. change it from 9999 to 9998). This account should be the one that you are logged in as or the user account that is experiencing the issue. I used the Administrator account as an example.

    Click OK and close the window. Close ArchestrA IDE and re open it. The issue should be resolved.
checked out objects
Give feedback about this article

Recommended articles

TN 1394 Error when Deploying: Remote Node's UserID/Password don't match GR Node's

Read More

TN 1366 Managing your Standalone InTouch Application in the Galaxy

Read More

TN - AppSrv - 16040702 Resolving "Open: Memory on the computer is low. New editor can't be launched."

Read More

TN 1040 No Alarms in Window Viewer

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand