Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Application Server
  • AVEVA Application Server Tech Notes

TN Appsvr160 How to prevent a computer running Application Server from turning off a NIC to save power

Last updated: March 6th, 2025

Description

  • Author: Joe Hefner
  • Published: March 6th, 2025

Details:

Description

Sometimes a computer or virtual image can turn off a NIC in order to save power. This can negatively effect the Wonderware Application Server communication or in a redundant environment cause a failover to occur. This tech note walks through a process for making sure this doesn't happen.

  • Author: Joseph Hefner
  • Published: 10/15/2015
  • Applies to: Application Server 3.1 and above

Details

When the NIC power issue occurs you will usually see warning messages for the MessageChannel similar to the one below:

CFMCObj::IssueRead - tagPlatformContext::GetConnection hSocket 14a8 failed

To prevent the computer from turning off the NIC follow the steps below:

Step 1:

From Control Panel \ Network and Sharing Center click the "Change Adapter Settings" link

Step 2:

Right click on the adapter and choose properties:

Step 3:

Click the Configure button:

Step 4:

Select the "Power Management" tab:

Step 5:

Uncheck the checkbox for "Allow the computer to turn off this device to save power":

The next thing to check is to ensure the the TOE is disabled. The article below walks through the process for checking this:

http://knowledgebase.progress.com/articles/Article/P163165

  1. Launch command propmt as an Administrator
  2. Use the command below to see if it is disabled:

    netsh int tcp show global 
     
  3. If it is enabled you can use the command below to disable it:
    netsh int tcp set global chimney=disabled

To change the TCP Chimney Offload setting on the network adapter in line with the Operating System setting above:

  1. Start -> Network Connections or Start -> Run -> ncpa.cpl
  2. Choose the network adapter in use.
  3. Right click and choose Properties
  4. Select the Configure button
  5. Select the Advanced tab where all features related to TCP Chimney offload available on the Network card are listed. The configurable options available vary depending on how the vendor implements their driver for Windows. Most network cards have features including Receive Side Scaling, TCP Checksum Offload and TCP Large Send Offload. 
  6. Change the related value setting to Off/Disable or On/Enable as appropriate. Refer to the vendor’s documentation for specific steps on how to disable these features.

The article below describes the TCP chimney:
https://support.microsoft.com/en-us/kb/951037#/en-us/kb/951037

prevent power-saving
Give feedback about this article

Recommended articles

TN 1394 Error when Deploying: Remote Node's UserID/Password don't match GR Node's

Read More

TN 1366 Managing your Standalone InTouch Application in the Galaxy

Read More

TN - AppSrv - 16040702 Resolving "Open: Memory on the computer is low. New editor can't be launched."

Read More

TN 1040 No Alarms in Window Viewer

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand