TN Appsvr112 Galaxy Style Library - Configuring Alarm Borders

Last updated: March 7th, 2025

Description

  • Author: Brian Schneider
  • Published: March 7th, 2025

Details:

Description

System Platform 2014 R2 introduced the ability to set custom element styles within Archestra Symbols. The Galaxy Style Library holds the default configuration for element styles utilizing the Element Style and Alarm Border animations. This article provide an example of configuring the Galaxy Style Library's Alarm Border configuration. 

  • Author: Michael Walker
  • Published: 03/19/2015
  • Applies to: System Platform 2014 R2

Details

Before editing Galaxy Styles, it is important to understand what drives the Alarm Border Element Styles. In the Archestra IDE click on the Galaxy -- Configure -- Alarms and Events Configuration. The Alarms section allows you to configure global settings for Alarm Severity, most importantly is the priority range as Attribute alarm configuration will determine the specific alarms severity. Below is a screenshot of the Alarms and Events Configuration Editor:

To configure Galaxy Element Styles, in the Archestra IDE go to Galaxy -- Configure -- Galaxy Style Library. 

Click on the "Element Styles" tab. Note this list contains all of the default Galaxy Styles that can be modified. 

Scroll to the "AlarmBorder_" section of the Element Style Overrides list (towards the bottom). 

Find the specific AlarmBorder you want to update and use the configuration panel on the right to set the override settings. Valid configuration consists of Text, Fill, Line and Outline.

Below is a screenshot showing the AlarmBorder_High_UNACK's configuration overridden to display a red outline instead of the default yellow outline. 

Within an attributes alarm configuration, the alarm is set to a priority of "High", remember this is based on the "Alarms and Events Configuration" above. Below displays an Attributes alarm configuration, with a priority of 400, which falls into the High alarm severity range. 

Below show an example of a Graphic Element using the Temperature Attribute above to animate the Alarm Border. 

In runtime, if the Hi Alarm is true, or an High Severity alarm is true within the galaxy, the associated element style of Archestra Graphics will use the Red Outline as defined within the Galaxy Element Styles. An example of this is below. 

 

alarm borders configuration
Give feedback about this article

Recommended articles

TN 1394 Error when Deploying: Remote Node's UserID/Password don't match GR Node's

Read More

TN 1366 Managing your Standalone InTouch Application in the Galaxy

Read More

TN - AppSrv - 16040702 Resolving "Open: Memory on the computer is low. New editor can't be launched."

Read More

TN 1040 No Alarms in Window Viewer

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand