TN MDT105 After installation of Autosave for System Platform. You want to change maintenance email address
Description
After installation of Autosave for System Platform. You want to change maintenance email address
- Author: Mike Viteri
- Published: 12/4/2017
- Applies to: Autosave for SP 6.02
Details
During the Autosave installation you were prompted to enter an email address and outgoing smtp server.
There isn't an easy way to change this email address or smtp server after the installation is complete.
To change the SMTP Server and/or the email address. You will need to open the Autosave database within SQL Server Management Studio.
Expand the tables and select the dbo.SC_Siteconfig
You can right click on the table and select "Edit top 200 rows".
Next you will see SMTP_HOST & SMTP_USER. Modify these fields with your new informaton.
Now go into Autosave for SP application. Go to the Tools Menu->Select A4SP Service.
Now the new sending address will be reflected from emails that come from Autosave.