TN IT298 How to modify InTouch Access Anywhere so that it only makes one application available

InSource_Logo_Transparent (1).png

 

Description

 

This article from InSource shows a technique for making only one application show up in Intouch Accesss Annywhere.

  • Author: Joseph Hefner
  • Published: 11/15/2017
  • Applies to: InTouch Access Anywhere 2014 R2 or above

Details

  1. Navigate to C:\Program Files (x86)\Wonderware\InTouch Access Anywhere Server\WebServer\AccessAnywhere and make a backup of the Start.html file.
  2. Open the file with Window notepad and remove the applications that you do not want to be listed from the option section.  Leave only the option that you wish to be selectable. In the screenshot below on the first application , demo1 -aareactordemo will be left as selectable from the Access Anywhere page.

Capture1.jpg