Skip to main content
InSource Solutions

TN Hist232 Installing Microsoft SQL Server 2012

insource logo large.jpg

 

Description

How to install Microsoft SQL Server 2012 for Wonderware Products

 

  • Author: Peter Farrell
  • Published: 09/29/2015
  • Applies to: SQL Server 2012

 

 

Details

Products included in Wonderware System Platform 2012 R2 (Historian/Historian Client, Wonderware Application Server, and Wonderware Information Server) support 32- and 64-bit versions of SQL Server 2012, but only for Standard Edition and Enterprise Edition. Only the 32-bit version of SQL Server 2012 Express Edition is supported.

 

Following are step-by-step procedures to install Microsoft SQL Server 2012 on a 32- or 64-bit operating system for all Wonderware Products that support/run with MS SQL Server 2012

 

You should allow approximately 1-2 hours to complete the installation.


Insert the SQL Server 2012 installation DVD into your DVD drive. If the autorun feature on your DVD drive does not launch the installation program, navigate to the root of the DVD and double-click Setup.exe. You will see the SQL Server Installation Center:


Figure_001.png

 

Important: SQL Server 2012 is not supported for versions prior to System Platform 2012 R2. For more information, which product is supported with what SQL Server version, please see the Database Compatibility Matrix on the Wonderware Developer Network.

Click the Installation item and then New SQL Server stand-alone installation (Figure 2 below).


Figure_002.png
 
This installation runs the Setup Support Rules operation. This operation identifies problems that might occur during the installation of SQL Server Setup Support files.


You must correct all the problems before the install can continue.

 

• Click the Show Details button to see the status of the rules (see below)


Figure_003.png

 

Click OK.

 

On the Product Key dialog box, click the Enter the product key option. The embedded product key should appear in the field. 


Figure_004.png

 

Click Next and review the license terms. Click I Accept the License Terms and then click Next.


Figure_005.png

 

On the Install Setup Files wizard, click Install to continue with the support files installation.


Figure_006.png

 
When the Support Files installation is finished, resolve any Failed Status messages and click Next.


Note: Using Windows Firewall is optional. If it is enabled, you must make sure the appropriate ports are open to enable remote access for SQL Server. You can proceed with the SQL Server installation and configure the ports later if desired.


Figure_007.png

 

Select SQL Server Feature Installation from the Setup Role screen, and click Next.


Figure_008.png

 

Select the features shown in Figure 9 (below) and click Next.

 

• Reporting Services is optional for most Wonderware components, but may be required for use with Wonderware Information Server (WIS) integration, depending on your choices during product installation.


• SQL Server Replication, Full-Text Search, Analysis Services, and Integration Services are optional selections that do not impact functionality but may be useful under various circumstances.


Figure_009.png

 

Click Next. The Installation Rules windows appears.


Figure_010.png

 

On the Instance Selection dialog box, click Default instance (Figure 11 below). Wonderware Products currently do not support Named Instances. 

 

• Accept the default Instance ID and Instance Root Directory.


Note: MS SQL 2012 Express Edition is supported for some System Platform 2012 R2 components. If you are installing MS SQL 2012 Express, make sure it actually installs the Default instance. There is an issue in the Express install that even if you select the Default instance required by the Wonderware Historian, it still results in the database engine being installed as the instance named SQLEXPRESS.

As a workaround, you can select the option to install a Named instance and provide MSSQLSERVER as the instance name (see the information about CR L00090827 in the Historian's Readme file).


Figure_011.png

 

Click Next.


Confirm the Disk Space Requirements and click Next (see below)).


Figure_012.png

 

In the Server Configuration window, accept the defaults and click Next (Figure 13 below). 

Additionally you can use a local account by clicking the drop down in the Account Name and browsing for the local system account. Most users should choose NT AUTHORITY\NETWORK SERVICE.However, corporate IT policies or network configurations may require you to specify a different account.


Figure_013.png

 
If you are installing MS SQL Server on an English operating system, proceed to Step 21 (below) to continue the installation. 

If you are installing MS SQL Server on a non-English operating system, click the Collation tab and select SQL_Latin1_General for the Database Engine collation. If you are also installing Analysis Services, its collation setting is Latin1_General_CI_AS (Figure 14 below).


Figure_014.png

 
If you find any other collation, change it to SQL_Latin1_General by clicking the Customize button next to Database Engine collation field.


Then, select SQL_Latin1_General_CP1_CI_AS from the list (Figure 15 below).


Figure_015.png

 

Click the Customize button next to Analysis Services collation and select Latin_General from the list (Figure 16 below). 


Figure_016.png 

 
Click OK then Next.


On the Database Engine Configuration screen, select the Mixed Mode (SQL Server authentication and Windows Authentication) option in the Account Provisioning tab (Figure 17 below). Mixed Mode (SQL Server authentication and Windows authentication) is optional but strongly recommended.


Type a password for the built-in SQL System Administrator account (sa). You must configure the sa-level with a strong password for security purposes.


Click Add to add any users who you want to have administrator rights when using Windows authentication. In this example, the local computer’s Administrator user is visible (Figure 17 below). You may also wish to click on the Add Current User button in order to add the user account of the person performing the installation.


Figure_017.png

 

Click the Data Directories tab to review all the directories then click Next (Figure 18 below).


Figure_018.png

 

If you chose to install Reporting Services, click the Install and Configure option and click Next (Figure 19 below).


Figure_019.png

 
Accept the default settings for the rest of the installation sequence. The installation will then proceed and you will see each module install.


Figure_020.png

 
When the Installation Configuration Rules check is complete, click the Show details button, resolve any failures, and click Next.


Figure_021.png

 
On the Ready to Install screen, click Install (Figure 22 below). 


Figure_022.png

 

When the setup process completes, all of the feature installations in the Installation Progress screen should show Succeeded in the Status column (Figure 23 below). Click Close to finish the installation.


Figure_023.png