[ISS Support Case] Unable to Boot Multi Screen Hardware Limitation Inquiry 2473 G UNO Thin Manager

Last updated: March 7th, 2025

Description

Trying to add a device to thin manager but thin manager doesnt boot on the system Do you have SME / clarification on UNO multi session and multi monitor enabled (AdvanTech). Looking over the manual for UNO-2473G and it appears it is not. Would like to have two screens on a few of their systems and currently they can only see one. When you enable multisession it seems to brick consistently V12.1 Thin Manager Server 2019 When set up multi session with a particular terminal client and the UNO associated with it. Results in endless boot loops (rebooting) Fail Again, Reboot, Repeat. The odd thing is that it not permanently broken ...technically If you go into this boot loop and delete the terminal client and you give your device a new addresses it does seem to comeback. But you have to repoint it at the IP address and the other device. In the manual under multi session, it has applied suggestions regarding editing local group policies (limit the number of users) - warning that if you do not explicitly have a multisession enabled device that you will run into issues / it will not work. So the suspicion it's a hardware limitation. The 2473 G come into 2 flavors 1 is a thin client (no HD) 1 is a thick client (HDD) Checked that the one they have is thin manager enabled and was under the impression from sales that it was ALSO multi session enabled (2473 G) If it's a hardware limitation needs: Quote on device - 1 ethernet - 24volt power supply - VGA port - HDMI port - Multi session screen / compliant Device

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: Thin Manager
Version:
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/04/2023
Case: 83619
Give feedback about this article

Recommended articles

[ISS Support Case] Thin Manager 14.01 License Acquisition Failure

Client reached out because one of the terminal servers was not acquiring a license from the Thin Manager server and presenting the following error: "No Thin Manager Terminal License Available on Server ."

Read More

[ISS Support Case] Cant remote into any thin clients

Thin client, trying to log in to server, one not letting him in kicks him out immediately started this morning

Read More

[ISS Support Case] Thin Manager License Not Activating Already Activated

In the thin manager web site to activate them being told they are already activated. Has no way of telling who that is, suspects it could be the client but wants to make certain before reaching out. TM Version 13.2 Need Serial Number Why reason for reset

Read More

[ISS Support Case] Unable to Connect Node to Thin Manager

Launching a new touhcpanel and cannot get Thin Manager to accept the configuration

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand