Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • Supporting Technologies (i.e. Windows / SQL Server / VMWare / etc.)
  • Supporting Technologies Tech Notes

TN WW124 Set Internet Explorer (WebBrowser control) compatibility mode

Last updated: March 6th, 2025

Description

  • Author: Brian Schneider
  • Published: March 6th, 2025

Details:

Description

Would like to disable Internet Explorer's compatibility mode. This is useful when applications embed Internet Explorer's WebBrowser control into their software but hide the toolbars, preventing you from manually setting this option.

  • Author: Dillon Perera
  • Published: 08/18/2015
  • Applies to: Internet Explorer versions 9, 10, 11

Details

When using software like the Archestra IDE with Wonderware Workflow, there may be times that information is displayed via a WebBrowser control. The content delivered via the WebBrowser control will not use the settings used within regular Internet Explorer. For content to be delivered correctly, you may need to disable Compatibility Mode for the WebBrowser control.

You can modify the Windows Registry to set the compatibility that should be used.

For 32bit:

HKEY_LOCAL_MACHINE\SOFTWARE\Microsoft\Internet Explorer\MAIN\FeatureControl\FEATURE_BROWSER_EMULATION

For 64bit:

HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\Microsoft\Internet Explorer\MAIN\FeatureControl\FEATURE_BROWSER_EMULATION

Create a new DWord for the name of the program that uses the Webbrowser control, such as aaIDE.exe. Set the value of this to the Compatibility level that should be forced:

  • "9000" - Use Internet Explorer 9 settings
  • "10000" - Use Internet Explorer 10 settings
  • "11000" - Use Internet Explorer 11 settings

Example of setting the Archestra IDE (aaIDE.exe) to use Internet Explorer 11 settings instead of Compatibility Mode:

 

ie compatibility web control
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand