TN 1056 Adding an IndustraForm Dashboard to j5

Last updated: March 5th, 2025

Description

  • Author: Ron Tanner
  • Published: March 5th, 2025

Details:

Description

Adding an IndustraForm Dashboard to j5

  • Author: Ron Tanner
  • Published: 12/17/2020
  • Applies to: j5 International

Details

Please note: Information indicated in red are constants and should not be changed.

Step 1:

  • In the module that needs a dashboard add the file named 'industraformdashboards.yml'.

  • Add the following details in the 'industraformdashboards.yml' file:

schema: "industraformdashboards" 

version: "1.0" 

--- 

industraformdashboards:
custom:
 title: "Custom Dashboard"
industraform_spec: "j5.WorkInstructions.FormDashboards.test"

Step 2:

  • Add a folder named 'FormDashboards' in the same module and create a file with the extension . form.yml into that folder with the same name as referenced in the .yml config file in step 1. In this case test.form.yml

  • Copy the code of the IndustraForm created from the File tab in designer and paste it in the form.yml file. In this case paste it in test.form.yml file.

Step 3:

  • Add a module.yml file to the FormDashboards folder with the following details:

version: "1.2" 
schema: "module" 

--- 

{}

Step 4:

  • Add relevant permissions to the folder that contains the industraformdashboards.yml file. Please note permissions should be assigned to the section name mentioned while creating the industraformdashboards.yml config file. In this case its ‘custom’. (Refer Step 1)

Step 5:

  • Run j5.

Notes: 

  • Changes to the IndustraForm are loaded on the fly, no need to re-start j5 
  • If want to add an entirely new dashboard then a re-start is needed, no need to run Setup Wizard though 
  • Hiding the 'Form Version', Note, Flag and submission section 
  • Check j5 start up - for the start of the dashboard’s app, etc.

Limitations 

  • Drill Down into other dashboards is not supported
  • Cannot export the dashboard to .pdf 

 

dashboard integration
Give feedback about this article

Recommended articles

TN 1469 Creating an Industrial Graphic directly from a Tag in 2023 R2

Read More

TN 1393 Deleting Tags from AVEVA Insight

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand