Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA License Manager
  • AVEVA License Manager Support Cases

[ISS Support Case] License issues

Last updated: March 6th, 2025

Description

They tried reserving the licenses. 23.0.04 They have redundant io servers. One is grabbing a license and the other one is not. ------------ Checking with AVEVA to see if fix in 4.1 applies to non-https envs as well. 1 system is not acquiring a license. Customer cannot upgrade the license manager. Redundant license servers. They want to do testing on this node.

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: License Manager
Version: 3.7
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 11/07/2024
Case: 88189
Give feedback about this article

Recommended articles

[ISS Support Case] IDE License Acquisition Failure

Client reached out due to when trying to utilize one of several IDE's the license must be dropped in order to open the IDE (consume the license on a different server).

Read More

[ISS Support Case] Trend application failing to acquire a license

LVM: Support issue at NEG fiberglass. A trend application is not acquiring a license from a new flex license server with current 2020 licenses activated. Not mission critical but does need to be addressed as quickly as possible. Migrating customer (temp migration on tier 2) Screen shot 20 pack and historian ongoing issue since July Licensing 4.0.1 installed caused lots of issues

Read More

[ISS Support Case] Floating License Manager Error V 2.8.00

Client reached out due to License Manager showing error message "Out of License". This is in relation to Citect Plant SCADA 2018.

Read More

[ISS Support Case] Redundant license servers broken

Hardware change with license servers.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand