AVEVA Insight Support Cases

[ISS Support Case] Aveva Insight not displaying data OpenConnection to Historian Online failed error = 236

Data is not showing up in Insight. Widgets are not showing a tag associated with them.

Read More

[ISS Support Case] Solution enquiring for: Insight Rest API integration

We are unable to fetch data from objects with name "Summaries" as shown below using REST API endpoint using both authentication and API key. We tried it with Power BI, Postman and Python program. Appreciate if you can assist with it. Client is attempting to setup custom script and query to export/connect Equipment Efficiency summary data into third party application.

Read More

[ISS Support Case] Trends quit working after a power outage

VM Trends stopped working after they lost power.

Read More

[ISS Support Case] No data in Insight

new installation they were seeing data a few days ago they are getting data in edge they've tried using different browsers and on different computers "failed to retrieve content details"

Read More

[ISS Support Case] Insight OEE issue

The customer has been doing some validation and they have a question that were unable to answer for them and are looking for some technical assistance. Within Insight, when they go to the OEE Analysis and select a Line, and then dive into the details for OEE we get the nice bar chart showing hourly OEE; however, when we add the Lines OEE tag to a bar chart for dashboarding purposes the values are different and do not line up or are completely missing for the same hourly buckets. In the past weve been asked for the Solution ID for Insight which is: Below is a screenshot side by side depicting what they are seeing (also attached the image so you can see it easier):

Read More

[ISS Support Case] Insight not publishing data

Client is pushing OPC Data to a PI Historian and to the InSight cloud. OI Gateway it grabbing data from PI Historian and they are using the InSight publisher to push the data to InSight. Version of InSight Publisher. 4.5.0

Read More

[ISS Support Case] InSight not receiving Data

Client called in because when viewing Insight all data was frozen on bad quality. Advised client to check status of Insight replication server awaiting response.

Read More

[ISS Support Case] Insight app is not working on any device

insight app is not working on any device insight outage due to updates

Read More

[ISS Support Case] Insight Publisher Installation Setup Failed

Historian 2014R2

Read More

[ISS Support Case] Failure To publish new Data Source InSight

Client reached out as when trying to republish data source\csv with 3 additional tags the 3 tags would not show up. When trying to republish the CSV as a new data source it would not show up in the list of data sources at all.

Read More

[ISS Support Case] Insight Publisher, New Tag's Trending Slow.

3/15/2023: -Insight Publisher, -Added new tag's 2/24/2023, updated through Excel, opens insight publisher, continue with publisher. -All values are matching, storage rates, storage type. -Allen-Bradley PLC, Gateway between control network and office network. Insight on office side. Pulling tag through control network from PLC. -Insight publisher is used as a Grapical interface to show what the Bit's in the PLC are showing. 185 tag's, Added 6 new tag's. -There is data there when opening the trending, just not updating as quickly as needed. 1,000-1,200Lb flow weight. 8 eight pull rate. -Trending is typically a long flat line maybe two steps a day. -3/15/2023: pulling 40 minutes now, seems good. -Should be updating every minute but, it's now updating every hour. PLC: ABCIP, control logix, 1756l82e, Version 32.1.4(Program Version?). -other tag's in the trending, motor tag, updating within seconds. 3/30/2023: -Still working with AVEVA and Will to resolve his "issue" Even though the data is populating and being seen and trending. Client still does not like the way it is trending or how slowly it is showing the trend on the Graphic.

Read More

[ISS Support Case] Average Value Calculation Question

Sees that the Average Value less than minimum value and is inquiring about the calculation

Read More

[ISS Support Case] Unable to Log into Insight

Users are receiving a log in failure when attempting to log in "We've detected multiple bad login attempts from this IP address. Please change your password or log in from another device"

Read More

[ISS Support Case] Unable to Create or Administer Users in Insight

Admin going to administration to add users Clicks on users list of recent users No option to create or edit current users. Has worked in the past, I click administration > Users . I would get options to manage users.

Read More

[ISS Support Case] Ehancement Request - Historian Web Client

Attaching a Enhancement Request Form to allow disabling the Windows Integration Security for Insight

Read More

[ISS Support Case] Aveva Insight

Customer States: "I have an immediate need. I cant seem to get to the administrative interface to add users. I have opened a ticket with Insource, but have not hear back. Has something changed with the Aveva Insight solution?"

Read More

[ISS Support Case] How can you delete local InSight content created by others

Read More

[ISS Support Case] ABCIP publishing to InSight stopped

The PC had done an update but the update has now been removed.

Read More

[ISS Support Case] Insight Replication from Historian Tier 2, not populating.

Replication is not working. -Some particular Tag's are stopped, not going to insight since last November. -From tier 2 Historian can see the data for the past year. -Real Tag's (Coming from external data, From a dump, Put's these tag's into a data file). -The data does happen in Historian Tier 2 environment.

Read More

[ISS Support Case] Historian Replication to Insight fails

I am having an issue registering the replication server with Insight. I can ping the IP from the server but I get an error when I try to register it.

Read More

[ISS Support Case] Insight Publisher MQTT Gateway

Trouble getting the MQTT gateway to work for publishing to insight. Advantech Wise 2410 LoRaWAN Gateway -> to -> MQTT.fx The data coming from our publisher from our other drivers are working with no issues. Can export a sample CSV,

Read More

[ISS Support Case] Aveva Historian Client Web

Web Client is incorrectly using linear interpolation Desktop Client is correctly using stairstep interpolation All tags are set to use system default How does one force these particular pens to be have like the others in client web?

Read More

[ISS Support Case] Insight Replication Email - this source was automatically disabled because

Recieved an email direct from AVEVA: ...this source was automatically disabled because the source was consistently sending data from across a very broad time period... Historian 2023 R2 System Platform 2023 R2 MDAS attributes. Had a couple domain issues, might have been some time syncing issues.

Read More

[ISS Support Case] AVEVA Insight timestamp discrepancy when changing Y-Axis settings

AVEVA Insight saw an issue see if they could get it address / bring to light. we noticed one of our power users using a lot this week (clod weather) noticed I can browse into on of our content (two different tanks) looks at data hover over and see data point puts cursor graph se value and time properties >Visual settings > YAxsis Y axes can be set to single, multi, stacked switch to multi or stacked the line above shows 7 hours ahead timewise heartburn just making sure the data is accurate is it looking at Going into stacked view like that just to make you are looking at the proper data & time relationship. stacked shows wrong goes back single shows good again. Ultimately needs to get

Read More

[ISS Support Case] Enabling 2FA Locked Client out of AVEVA Connect Account

I by accident enabled a two step authentication to which your software/cloud access was not configures. Now i cannot access my account. I need some help in getting this resolved. I've been trying to get help for 2 weeks now. I used Aveva Connect to access Wonderware datapoints. Without access to this site i am completely blinded to what's happening in the facility.

Read More

[ISS Support Case] InSight Missing Data Flatlined

Client reached out due to flat lines (missing data over 3 days) when viewing InSight.

Read More

[ISS Support Case] Insight data source disabled

Received 2 emails regarding InSight data source being disabled. This is caused by 50 days of data getting pushed at once. They working on something with Tier2 historian that probably sent a bunch of blocks.

Read More

[ISS Support Case] NA Insight Solutions - Multiple Sources Offline

Multiple Data Sources are showing offline. They don't look to be blocked as I can still see the Source inside Insight. There are several Sources that are still replicating.

Read More

[ISS Support Case] InSight - Data Source Disabled Again

Customer said he had this issue a few times, the most recent being last month. They had an improper shut down to the data source

Read More

[ISS Support Case] InSight Login Failure

Client reached out as user is experiencing issues logging into InSight where the multi factor authentication code fails.

Read More

[ISS Support Case] Insight User Replaced Phone Needs MFA Reset

An Insight user replaced his phone and is unable to access any data. Needs MFA reset Familiar with the process.

Read More

[ISS Support Case] Insight data blocked - Benson site

Your AVEVA Insight data source triggered automatic system protections and blocked incoming data from:

Read More

[ISS Support Case] Locked out of insight

Connect account has authenticator enabled, but they don't recall enabling them

Read More

[ISS Support Case] Insight redirected to aws europe

Aveva insight issue affecting service for customers in us and eu regions

Read More

[ISS Support Case] InSight Login Failure

Client reached out as two users are experiencing issues logging into InSight where the authentication codes fail. They are using different authentication applications. The user do not have their security codes for an account reset.

Read More

[ISS Support Case] Insight

Customer is running AVEVA Historian 2017 Update 3 Service Pack 1 on Windows Server 2016. They report that while they can successfully see data within Historian and Historian Client, no updated data is being reflected in AVEVA Insight. Discovery Session (initial call) Verified Historian is logging and trending data locally. Insight connection showed no new data replication. When reviewing licensing in the AVEVA SMC under Historian ? Status ? All Tasks ? View License Information, replication appeared as Not Allowed / unlicensed (screenshot attached). Attempted to apply a 30-day demo license to enable replication. Activation failed with error: Unable to activate License. Activation ID () is invalid or does not exist. Please verify or contact local Wonderware or AVEVA representative. Store-forward folders were checked under C:\Historian\StoreForward. Logs indicated a switch to store-forward mode, but no data was written to the folder. Logs showed replication errors: Main Replication failed to replicate source tag BackLVDTraw.PV to destination tag BackLVDTraw.PV (tag handle 10000208, client handle 3), error = 243 (Connection blocked) [DANWNDRSQL3; simplereplication.cpp; 107] BRF_Insight: Storage switched to StoreForward, event='MaxTimeInNoStorageReached'[clientacces, 1045], SF State ='SFTagSynchronized' [storagestate.cpp, 123]

Read More

[ISS Support Case] What's the maximum number of monthly users for an InSight solution

I need to know the maximum number of monthly users for my current solution. I would also like information about increasing this number of users

Read More

[ISS Support Case] Insight Alerts Delayed By Multiple Hours

Alert notifications from Insight are being delayed by multiple hours

Read More

[ISS Support Case] Insight Alerts Delayed By Multiple Hours

Alert notifications from Insight are being delayed by multiple hours

Read More

[ISS Support Case] AVEVA Insight Max Number of users for a solution

Question for AVEVA insight is there a max number of users? how does that work? Would like quote for 2 additional users.

Read More

[ISS Support Case] AVEVA Insight Max Number of users for a solution

Question for AVEVA insight is there a max number of users? how does that work? Would like quote for 2 additional users.

Read More

[ISS Support Case] Not able to register user on Insight

General error

Read More

[ISS Support Case] Not seeing downtime on InSight Performance

The client is currently not seeing any data updates in InSight.

Read More

[ISS Support Case] Insight Publisher Data Delay

- Have a set up streaming data from a site using Publisher, Gateway and Cimplicity Has noticed its talking up to half an hour to see data on Insight trying to figure out were the delay is. No errors or messages in logger. Other sites with same set up do not suffer this issue. looking at Gateway in diagnostics sees data Using CDP 7.2.200 Did some clean up in this system and re published with a new version of the publisher. Started seeing this issue over the past two days AVEVA insight publisher 4.4.0

Read More

[ISS Support Case] Only able to see the last five minutes of data in InSight trends

Only able to see the last five minutes of data in InSight trends

Read More

[ISS Support Case] Unable to Log into Insight

Receiving a license violation when attempting to sign in with a particular account

Read More

[ISS Support Case] Insight Solution Configured Incorrectly

Client is checking the performance of a line in AVEVA Insight and OEE is 600% at 11am. Trying to go live people from Optel who set up his system, all of his lines were set up as equipment he needs his lines to contain equipment. A line of production has different components Optel set up entire line as a single equipment so there is no granularity. (is solution Administrator)

Read More

[ISS Support Case] OEE Analysis is Blank

It appears in the line KPIs but not in OEE Analysis

Read More

[ISS Support Case] Performance is wrong

Performance in line 2 is very wrong it is impossible to have this number. It is happing when the operators change the number of balls in a production. It is happening frequently, but the OEE should be lower, not this high value. Can you fix it automatically? Removing the outliers automatically. We need see all lines in this graphics. Where is the lines 6 and 7? Could you add it there. Please.

Read More

[ISS Support Case] Insight Inquiry Managing Users

One of our clients recently got insight and installed it. Researching the configuration of User Groups on Insight, from the AVEVA site it sounds like you also need to be an Administrator in Insight Connect, looking for a little clarity on this.

Read More

[ISS Support Case] AVEVA Insight O365 link

Can you use Office 365 for authentication into Aveva Connect?

Read More

[ISS Support Case] Unable to Retrieve Data

Added new tags to Insight via Insight Publisher. They appear in the application, but when accessed the page produces "cannot retrieve data"

Read More

[ISS Support Case] Insight Alert deleted but still alerting

Client has an alert in Insight that has been deleted but it is still being triggered every 3 minutes.

Read More

[ISS Support Case] Replicated Data to Insight Doesnt Match Source

Historian data being replicated to Insight shows different values once in Insight.

Read More

[ISS Support Case] Aveva Insight - unable to login

Aveva Insight - logged in and it is asking for company info, cannot click submit.

Read More

[ISS Support Case] Insight Source Not Sending Data

Data from Studio Gateway stopped reporting to Insight after an IP change

Read More

[ISS Support Case] AVEVA Insight Tag Type Change

Is there a way to change the tag type for AVEVA Insight tags from Float to DoubleStringByte? I need to change 100+ tags

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand