TN AppSvr228 Remote IDE connection error "unable to connect to galaxy check logger for details"
Last updated: February 26th, 2025Description
- Author: Brian Schneider
- Published: February 26th, 2025
Details:
Description
When connecting to a galaxy using a remote IDE you get the error "unable to connect to galaxy,check logger for details"
- Author: Mike Viteri
- Published: 2/17/2017
- Applies to: Application Server
Details
When attempting to connect to a galaxy using a remote IDE you get the error below:

This happen because you don't have the user from the remote IDE added to the file repository folder on the GR.
Go into the GR and find the FileRepository folder. Add the user you want to have permission to connect remotely.
NOTE: You can add everyone as a security group but this is at your OWN RISK!

Once you change these settings you should now see your remote galaxies.