Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Plant SCADA
  • AVEVA Plant SCADA Support Cases

[ISS Support Case] Upgrade to 2018 R2 Broke Communication on a Backup PC

Last updated: October 17th, 2025

Description

Upgraded to Citect 2018 R2 on one (Primary) PC set it up and connected everything back and were able to connect to other servers for statistical data, everything checked out. Proceeded with the upgrade on the second PC (back up) and lost all communications on that particular computer. No settings have been changed. Can Ping everything, reached out to IT to verify not a Firewall issue. Suspect it is not because they moved the system to the same LAN and subnet as one of the servers they communicate to but were still not getting any data.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Citect
Version: 2018
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/20/2022
Case: 81760
Give feedback about this article

Recommended articles

[ISS Support Case] Deployment Failure

Client reached out as he can not deploy updated target version of project to client nodes. The settings in the deployment window can not be changed and are grayed out. This is after updating all nodes from 2018 Patch 15 to 2018 Patch 22.

Read More

[ISS Support Case] Cannot Install Client software on device.

I am trying to install Citect on an industrial computer that previously ran SCADA for a different plant. Installation is getting hung during floating license manager installation. Also, when try to run configurator the server will not show up under list of servers. IP address can be pinged from both sides.

Read More

[ISS Support Case] Driver question, system tag's

I am trying to communicate with a Siemens S7-1200 PLC using Plant SCADA 2023. Ive installed the S7TCP driver and was able to communicate using Symbolic Addressing (e.g. Tag_1, StartPump3, FlowRate, etc.). However, due to how the PLC was programmed, we have to use Absolute Addressing (e.g. %Q3, %QW1, %I9, %IW7, %DB20.DBD0, etc.). Can the S7TCP driver support Siemens Absolute Addressing?

Read More

[ISS Support Case] Citect, Alarm History error.

12/28/2023: -Button that say's alarm history. -"Network name cannot be found." -Needing help Exporting Alarm .CSV files.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand