[ISS Support Case] Log storage

Last updated: October 17th, 2025

Description

We are requesting support for an issue encountered after upgrading our AVEVA Plant SCADA system from version 7.5 to 8.5 (Update 10). In our current Citect 7.5 environment, we have alarms and logs configured in the devices.dbf file (configured in Plant SCADA Studio ? Setup ? Devices tab). For example, we have a log set to generate a text file whenever a user acknowledges all alarms by pressing a button on a screen. In version 7.5, these alarm and log files are successfully written to a single server file location, allowing all user actions from any client or server machine to be consolidated in one place. After the upgrade to Plant SCADA 8.5 Update 10, the behavior has changed: each machine (server or client) now stores changes made by users locally, rather than writing to a centralized server location. This requires setting up log and alarm folders on each client and server individually, then periodically backing them up or merging the files manually. This process is inefficient and time-consuming compared to our previous centralized setup. Request: Is there a workaround or configuration option that would allow devices.dbf to function in the same way it did in Citect 7.5logging user actions from all machines into a single server-based file locationrather than maintaining separate local copies on each machine?

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Citect
Version: 7.5
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 08/22/2025
Case: 98996
Give feedback about this article

Recommended articles

[ISS Support Case] Deployment Failure

Client reached out as he can not deploy updated target version of project to client nodes. The settings in the deployment window can not be changed and are grayed out. This is after updating all nodes from 2018 Patch 15 to 2018 Patch 22.

Read More

[ISS Support Case] Cannot Install Client software on device.

I am trying to install Citect on an industrial computer that previously ran SCADA for a different plant. Installation is getting hung during floating license manager installation. Also, when try to run configurator the server will not show up under list of servers. IP address can be pinged from both sides.

Read More

[ISS Support Case] Driver question, system tag's

I am trying to communicate with a Siemens S7-1200 PLC using Plant SCADA 2023. Ive installed the S7TCP driver and was able to communicate using Symbolic Addressing (e.g. Tag_1, StartPump3, FlowRate, etc.). However, due to how the PLC was programmed, we have to use Absolute Addressing (e.g. %Q3, %QW1, %I9, %IW7, %DB20.DBD0, etc.). Can the S7TCP driver support Siemens Absolute Addressing?

Read More

[ISS Support Case] Citect, Alarm History error.

12/28/2023: -Button that say's alarm history. -"Network name cannot be found." -Needing help Exporting Alarm .CSV files.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand