Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Plant SCADA
  • AVEVA Plant SCADA Support Cases

[ISS Support Case] Configuring OPC UA on Plant SCADA to communicate with our dynamic video wall.

Last updated: October 17th, 2025

Description

We require support to assist with configuring OPC UA on Plant SCADA to communicate with our dynamic video wall. We are utilizing Plant SCADA 8.50 Update 10. We have configured our Primary Citect server: Firewall allowances opened for our inbound port (48031). Outbound not blocked. Connected to System Management Server Good Security Roles setup Good Computer Setup: Password assigned and Runtime Manager As A Service checked Good Encryption enabled with encryption set to mixed mode Good CAN connect to our server via ProSys OPC UA Explorer. Certs installed. Good Issue: CANNOT Browse tags in project. Clicking on Browse does not display any tags Bad We are using Matrikon OPC UA browser to test, server to server communication, and with the Video Wall server attempting to connect and browse variable tags on Plant SCADA Primary I/O server.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Citect
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 07/14/2025
Case: 98357
Give feedback about this article

Recommended articles

[ISS Support Case] Deployment Failure

Client reached out as he can not deploy updated target version of project to client nodes. The settings in the deployment window can not be changed and are grayed out. This is after updating all nodes from 2018 Patch 15 to 2018 Patch 22.

Read More

[ISS Support Case] Cannot Install Client software on device.

I am trying to install Citect on an industrial computer that previously ran SCADA for a different plant. Installation is getting hung during floating license manager installation. Also, when try to run configurator the server will not show up under list of servers. IP address can be pinged from both sides.

Read More

[ISS Support Case] Driver question, system tag's

I am trying to communicate with a Siemens S7-1200 PLC using Plant SCADA 2023. Ive installed the S7TCP driver and was able to communicate using Symbolic Addressing (e.g. Tag_1, StartPump3, FlowRate, etc.). However, due to how the PLC was programmed, we have to use Absolute Addressing (e.g. %Q3, %QW1, %I9, %IW7, %DB20.DBD0, etc.). Can the S7TCP driver support Siemens Absolute Addressing?

Read More

[ISS Support Case] Citect, Alarm History error.

12/28/2023: -Button that say's alarm history. -"Network name cannot be found." -Needing help Exporting Alarm .CSV files.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand