Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Plant SCADA
  • AVEVA Plant SCADA Support Cases

[ISS Support Case] Citect development question

Last updated: October 17th, 2025

Description

Is there a good practice or work around to do the following; We are looking for way for multiple users to change graphics, trend, alarm on one computer where the project reside without backup/restore to another computer and then back/restore back to the deploy machine. Currently, we would do the following per the deploy machine and laptop. 1. We would back up the project 2. restore it on a laptop 3. Do the modification of multiple graphic 4. Backup the project on the laptop 5. Restore the project as Laptop_project2 6. Open all the modify graphics and save as to the deployment machines main project Is this the best practice or show we just copy modify graphics to the main project on deployment, open it and save as/save all? Is there any other way or suggestion?

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Citect
Version:
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 12/09/2022
Case: 82926
Give feedback about this article

Recommended articles

[ISS Support Case] Deployment Failure

Client reached out as he can not deploy updated target version of project to client nodes. The settings in the deployment window can not be changed and are grayed out. This is after updating all nodes from 2018 Patch 15 to 2018 Patch 22.

Read More

[ISS Support Case] Cannot Install Client software on device.

I am trying to install Citect on an industrial computer that previously ran SCADA for a different plant. Installation is getting hung during floating license manager installation. Also, when try to run configurator the server will not show up under list of servers. IP address can be pinged from both sides.

Read More

[ISS Support Case] Driver question, system tag's

I am trying to communicate with a Siemens S7-1200 PLC using Plant SCADA 2023. Ive installed the S7TCP driver and was able to communicate using Symbolic Addressing (e.g. Tag_1, StartPump3, FlowRate, etc.). However, due to how the PLC was programmed, we have to use Absolute Addressing (e.g. %Q3, %QW1, %I9, %IW7, %DB20.DBD0, etc.). Can the S7TCP driver support Siemens Absolute Addressing?

Read More

[ISS Support Case] Citect, Alarm History error.

12/28/2023: -Button that say's alarm history. -"Network name cannot be found." -Needing help Exporting Alarm .CSV files.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand