[ISS Support Case] Aveva Citect "Deployment is enabled but no project has been deployed".
Last updated: September 4th, 2026Description
I am having an issue deploying projects to our server/clients. When I attempt to deploy a new version, The server/clients are having a problem loading the new deployed version. The Runtime manager will say the status is "stopped" and when I press "Start All", I message will pop up saying "Deployment is enabled but no project has been deployed". I can confirm the project has, in fact, been deployed. I can see the deployed version has changed. In order for the Runtime manager to load the deployed version, I have to go into the "Computer setup wizard" and just click through the setup wizard by pressing "next" until I get to "Finish". I don't have to change anything in the setup wizard, when I get to the "Project setup" window it already has the new project version selected. Once I press "Finish" at the end of the setup wizard, I open the Runtime manager and it will load the new deployed version. The new deployed version will load BUT a message will appear saying " No protection key found. Press OK to run in Demo Mode?" When the project loads, I don't have any data exchange to/from Citect. All of the values are #COM. If I deploy a previous version of the Citect project, It works perfectly without issue.
- Author: Kevin Modlin
- Published: September 4th, 2026
Details:
| Product: Citect |
| Version: 2018 |
| Solution: [Solution is visible below when you're logged in and have a current subscription] |
| Date Created: | 03/25/2026 |
| Case: | 103311 |
Recommended articles
[ISS Support Case] Deployment Failure
Client reached out as he can not deploy updated target version of project to client nodes. The settings in the deployment window can not be changed and are grayed out. This is after updating all nodes from 2018 Patch 15 to 2018 Patch 22.
Read More[ISS Support Case] Cannot Install Client software on device.
I am trying to install Citect on an industrial computer that previously ran SCADA for a different plant. Installation is getting hung during floating license manager installation. Also, when try to run configurator the server will not show up under list of servers. IP address can be pinged from both sides.
Read More[ISS Support Case] Driver question, system tag's
I am trying to communicate with a Siemens S7-1200 PLC using Plant SCADA 2023. Ive installed the S7TCP driver and was able to communicate using Symbolic Addressing (e.g. Tag_1, StartPump3, FlowRate, etc.). However, due to how the PLC was programmed, we have to use Absolute Addressing (e.g. %Q3, %QW1, %I9, %IW7, %DB20.DBD0, etc.). Can the S7TCP driver support Siemens Absolute Addressing?
Read More[ISS Support Case] Citect, Alarm History error.
12/28/2023: -Button that say's alarm history. -"Network name cannot be found." -Needing help Exporting Alarm .CSV files.
Read More