[ISS Support Case] ViewApp Memory Issue
Last updated: September 4th, 2026Description
Application: view.exe Framework Version: v4.0.30319 Description: The process was terminated due to an unhandled exception. Exception Info: System.OutOfMemoryException at System.Windows.Media.Composition.DUCE+Channel.SyncFlush() at System.Windows.Interop.HwndTarget.UpdateWindowSettings(Boolean, System.Nullable`1) at System.Windows.Interop.HwndTarget.UpdateWindowPos(IntPtr) at System.Windows.Interop.HwndTarget.HandleMessage(MS.Internal.Interop.WindowMessage, IntPtr, IntPtr) at System.Windows.Interop.HwndSource.HwndTargetFilterMessage(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndWrapper.WndProc(IntPtr, Int32, IntPtr, IntPtr, Boolean ByRef) at MS.Win32.HwndSubclass.DispatcherCallbackOperation(System.Object) at System.Windows.Threading.ExceptionWrapper.InternalRealCall(System.Delegate, System.Object, Int32) at System.Windows.Threading.ExceptionWrapper.TryCatchWhen(System.Object, System.Delegate, System.Object, Int32, System.Delegate) at System.Windows.Threading.Dispatcher.LegacyInvokeImpl(System.Windows.Threading.DispatcherPriority, System.TimeSpan, System.Delegate, System.Object, Int32) at MS.Win32.HwndSubclass.SubclassWndProc(IntPtr, Int32, IntPtr, IntPtr)
- Author: Kevin Modlin
- Published: September 4th, 2026
Details:
| Product: InTouch OMI |
| Version: 2023 R2 |
| Solution: [Solution is visible below when you're logged in and have a current subscription] |
| Date Created: | 02/20/2026 |
| Case: | 102499 |
Recommended articles
[ISS Support Case] Trend not showing correct data from the previous day
Production machine that's been in production for a while Noticed the issue on the 20th They are unaware of any changes that could have caused the issue
Read More[ISS Support Case] OMI MapApp Configuration
Client reached out looking for guidance on configuring the MapApp.
Read More[ISS Support Case] Trend SQL DB Connection Issue
Client reached out due to receiging the following error when trying to login/connect to SQL DB within OMI Trends: "System.Security.Cryptography.CryptographicException: Key not valid for use in specified state."
Read More[ISS Support Case] OMI Alarm Client Not Re-Querying Properly
I am having a really hard time understanding why my alarm query is not updating according to the script I wrote up. I have a script that should change how the alarm client is queried based on the current navigation. It updates the query accordingly when I navigate from one layout to another. However, when I navigate from one screen to another (that uses the same layout), the alarm query refuses to update!
Read More