[ISS Support Case] InTouch OMI not receiving data after reboot.

Last updated: March 6th, 2025

Description

Client installed Microsoft RDS Cal on terminal servers. After rebooting server after install one of the terminal servers is no longer acquiring data. After going through this procedure the server is now receiving data, but the Platform and engine fail to startup/go on scan when the server is rebooted. It said it couldnt communicate with the engine. I logged onto the node and found that the platform had failed to startup. Below are steps I have taken: Manually started it off scan. Tried to set it to On Scan, but it failed. I opened the log viewer and tried again and it was successful. The Engine was off scan, so I set it on scan and it was successful. At this point the viewapp appeared to be running okay. Tried to redeploy the viewapp, but it became stuck on the orange icon. Undeployed the entire platform, then deployed each object 1 at a time, but it still became stuck on orange icon. Undeployed the entire platform, then restarted the node. Deployed the objects 1 at a time, but it still became stuck on orange icon. Followed Tech Note 845 (https://cdn.logic-control.com/docs/Wonderware/Tech%20Notes/Tech%20Note%20845%20-%20Resolving%20Orange%20Icon.pdf) and was able to deploy successfully. Restarted the server and it failed to start the platform. Manually started the platform and engine and ViewApp is working. Restarted the server again and it failed to start the platform. Manually started the platform and engine and ViewApp is working, but the engine is running off scan.

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: InTouch OMI
Version: 2023
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/24/2024
Case: 87116
Give feedback about this article

Recommended articles

[ISS Support Case] Trend not showing correct data from the previous day

Production machine that's been in production for a while Noticed the issue on the 20th They are unaware of any changes that could have caused the issue

Read More

[ISS Support Case] OMI MapApp Configuration

Client reached out looking for guidance on configuring the MapApp.

Read More

[ISS Support Case] Trend SQL DB Connection Issue

Client reached out due to receiging the following error when trying to login/connect to SQL DB within OMI Trends: "System.Security.Cryptography.CryptographicException: Key not valid for use in specified state."

Read More

[ISS Support Case] OMI Alarm Client Not Re-Querying Properly

I am having a really hard time understanding why my alarm query is not updating according to the script I wrote up. I have a script that should change how the alarm client is queried based on the current navigation. It updates the query accordingly when I navigate from one layout to another. However, when I navigate from one screen to another (that uses the same layout), the alarm query refuses to update!

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand