TN 1321 Unable to activate license with message "Unable to communicate with the Activation Server." For only one license serial number.

Last updated: February 26th, 2025

Description

  • Author: Brian Schneider
  • Published: February 26th, 2025

Details:

Description

This article from InSource shows how to resolve a failure to activate a license with message "Unable to communicate with the Activation Server." for only a particular license serial number.

  • Author: Peter Farrell
  • Published: 12/21/2022
  • Applies to: All versions upto and including 2020x

Details

Unable to activate license with the following message

"Unable to communicate with the Activation Server.
Ensure you have internet connectivity or proceed with offline activation by changing the activation settings."

If you are able to activate other serial numbers from the same License Server, but keep getting the above message for a particular serial number it is possible that the license serial number for which activation was being attempted has already been deployed at a different version release of the same serial number. The message presented is somewhat misleading because the license server could be reached for other activations.

You can check your License Server and look at the License Summary. If you see the same serial number with a dash # which is different, this could be the issue preventing activation and the misleading warning message shown above. The dash # appended to the serial number indicates that the serial number has been upgraded either functionally or to a later version. A dash number of 0 would be the original issue of the license.

If you find that a particular license serial number has already been activated, you would need to deactivate the license or purchase a new license with a different serial number.

communication error activation server
Give feedback about this article

Recommended articles

How to Check for On Hold Emails in Mimecast

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand