Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA License Manager
  • AVEVA License Manager Support Cases

[ISS Support Case] Supervisory Client - Read Only - User Reservation

Last updated: March 6th, 2025

Description

Reference case: 85868 ITAA - User-based License Reservation Reference case: 83189 ITAA - User-based License Reservation Customer has purchased an extra Read Only Supervisory Client License, originally just for ITAA but they can only use it in certain situations. The AELicMgr is not handing out a user-reserved license. Instead it is allocating an available (non-read-only) Supervisory Client license to the machine. Was able to work out a solution by deploying a read-only ViewEngine to the ITAA server, giving the read-only user a special URL to the ITAA server, but the user figured out that if he deleted the "_RO" from the URL I gave him, he could still sign in with his credentials and pull a full Supervisory Client license. I upgraded the AELicMgr on the customer's system to 4.0.1. This involved bringing down the License Manager Server, which is also the GR, rebooting into safe mode, then reloading a .DLL. The customer has connectivity to a DC. Worked with third-party IT provider to provision SCADA groups for this customer to use. Built a new test server, joined to domain. Installed SP 2020 R2 SP P01, Built a quick galaxy with OS Group Security enabled, then repeated the exercise with the License Manager. Not even in an ITAA environment, but running the OMI directly on the test server while logged in with domain credentials, the AELicMgr is still not using the user-reserved license. The only thing I think I could have fouled up was not configuring the System Management Server for the Test Server. This unfortunately is very risky because there is already an SMS on this network. As a general note, I have been battling this issue on-and-off since November 2022!

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: License Manager
Version: 4.0
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 03/20/2024
Case: 86331
Give feedback about this article

Recommended articles

[ISS Support Case] IDE License Acquisition Failure

Client reached out due to when trying to utilize one of several IDE's the license must be dropped in order to open the IDE (consume the license on a different server).

Read More

[ISS Support Case] Trend application failing to acquire a license

LVM: Support issue at NEG fiberglass. A trend application is not acquiring a license from a new flex license server with current 2020 licenses activated. Not mission critical but does need to be addressed as quickly as possible. Migrating customer (temp migration on tier 2) Screen shot 20 pack and historian ongoing issue since July Licensing 4.0.1 installed caused lots of issues

Read More

[ISS Support Case] Floating License Manager Error V 2.8.00

Client reached out due to License Manager showing error message "Out of License". This is in relation to Citect Plant SCADA 2018.

Read More

[ISS Support Case] Redundant license servers broken

Hardware change with license servers.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand