[ISS Support Case] License Manager Load Failure

Last updated: March 6th, 2025

Description

Client called in as they were receiving a 404 error when trying to access Enterprise License Manager. After setting no system management server in the SMC the client was now able to view the license manager, but was being prompted to sign in two times when opening license manager. Client signed in with windows domain account. After signing in when client would attempt to add server they would receive the following error: "Add Server failed for XXXXXX. Reason: License Server cannot be added to License Manager License Server components are not installed on the specified node (or) The License Server port is not opened (or) The License Server name is incorrect or the server is not accessible." Uninstalled and reinstalled License Manager/Server and the issue persisted. When troubleshooting further noticed that several components seemed to be missing including License Manager Web Service, License Server Core service, properties.xml file. Test connections were passing in Configurator and port 55555 was showing JLLSTranslator listening on port 55555.

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: License Manager
Version: 4.0
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 02/09/2024
Case: 86306
Give feedback about this article

Recommended articles

[ISS Support Case] IDE License Acquisition Failure

Client reached out due to when trying to utilize one of several IDE's the license must be dropped in order to open the IDE (consume the license on a different server).

Read More

[ISS Support Case] Trend application failing to acquire a license

LVM: Support issue at NEG fiberglass. A trend application is not acquiring a license from a new flex license server with current 2020 licenses activated. Not mission critical but does need to be addressed as quickly as possible. Migrating customer (temp migration on tier 2) Screen shot 20 pack and historian ongoing issue since July Licensing 4.0.1 installed caused lots of issues

Read More

[ISS Support Case] Floating License Manager Error V 2.8.00

Client reached out due to License Manager showing error message "Out of License". This is in relation to Citect Plant SCADA 2018.

Read More

[ISS Support Case] Redundant license servers broken

Hardware change with license servers.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand