[ISS Support Case] Remote IDAS to 2 Historians

Last updated: October 17th, 2025

Description

I need to install a remote IDAS on an Intouch HMI 2014 R2 node and have it provide data to both a 2014 R2 historian and a 2020 R2 SP1 historian. Is this possible? The 2014 historian will be decommissioned in July but I'd like to have the remote IDAS connect to both historians during the switchover. Also the upgrade to the HMI from 2014 R2 to 2020 R2 will likely not occur until later this year so I'd like to use the 2014 remote IDAS with the 2020 R2 historian if that is possible. I did install a test remote idas on the server i use for the 2014 Intouch development and WIS and could get it connected and configured to the 2014 historian. If i try and use it on the 2020 historian it appears to want to configure the remote idas again an not use the configuration from the 2014 settings.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 06/28/2022
Case: 81987
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand