[ISS Support Case] IDAS overflow recovery

Last updated: October 17th, 2025

Description

version historian 20,1,001,000 version of fsgateway 3.0.200 version is mature support toolkit version 7,2,1,14 os for fsgateway nodes is server 2008 In qualitymap table quality 20 IDAS overflow recovery In OPCQalityMap 20 Bad,Last known Value Suitelink stream communication failure receiving from aahidas connection for fsgateway went away app closed connection see also case 80339 see aveva case SR960148342 1. Run SSMS and execute the following query against the Runtime database (where ls starts with lowercase L): update StorageShard set CmdExtArgs='-ls' where ShardName = 'Main'; 2. Create a registry DWORD (32-bit) value with Name 'ForceValueOnReconnect' and set it to 1 under location below for 32 bit OS. HKEY_LOCAL_MACHINE\SOFTWARE\ArchestrA\Historian\Programs\aahClient and for 64 Bit OS. HKEY_LOCAL_MACHINE\SOFTWARE\Wow6432Node\ArchestrA\Historian\Programs\aahClient And the values started updating

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 04/18/2022
Case: 81324
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand