[ISS Support Case] Historian Installation Failure

Last updated: March 6th, 2025

Description

Client reached out as when he was trying to Install Historian 2020 R2 Sp1 he was receiving an error message stating: "Unsupported Operating System detected." After confirming the OS was compatible in technology matrix tried running Install in compatibility mode. The install got further this time but then failed with the following error message: "Prerequisite failed to install because of the following: "Install cannot continue. If you have an unsupported version of SQL Server already installed on this computer, please upgrade it to a supported version. Alternatively uninstall SQL Server and rerun this set Setup again to automatically install and use SQL Server Express" This node is a VM using a possibly unsupported virtualization software according to the "Virtualization and Fault-tolerant Environment Environment Compatibility:

  • Author: Kevin Modlin
  • Published: March 6th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/31/2024
Case: 87188
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand