[ISS Support Case] Historian Configuration Import Resulted in Error

Last updated: October 17th, 2025

Description

Following TN1048 had difficulties networking older historian, so decided to move to 2020. Exported configs from 2014 R2 SP1 system (either to a USB or team viewer cant recall) Now trying to import configuration in 2020 R2 P01. During the import started getting 'a lot of errors' (like each tag could not be imported) SMC: The following query did not succeed: . SQL Server reported the following error(s): TagHistory being imported is an active tag (update failed) Now historian modules are in a mixed state (some stopped some started) Now getting message : Circular storage location could not be accessed

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 02/08/2022
Case: 80929
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand