[ISS Support Case] Frozen Data in Reports from 12:00AM to 7:00AM Affecting Both New and Old Systems

Last updated: October 17th, 2025

Description

would like to revisit 97874. Having some issues with my Historian. Running InTouch 2023 R2 It seems like whenever the day rolls over and the new circular file is being created. Trends are unavailable for 6 hours period. On the trends everything is paused until the next days Historical data file is created. around 1:30 will see data again until the following day. Client runs ARFO which confirms the existence of an issue when pulling data during the 'frozen data' period. Data coming from a Managed intouch application using LGH files MDAS Tags pushing data to Historian (using history block's) Historian Trend .NET control Historian Trend Standalone application issue affecting multiple controllers From midnight - 6AM there are times where there is a blip of 15-20 minutes where the data is accessible but it goes away until after 12:30 PM

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Historian
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 07/30/2025
Case: 98541
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand