[ISS Support Case] Backup of Historian Server

Last updated: March 7th, 2025

Description

We are having a problem with the backup of our Historian server. Other functions of the Historian server are working as expected. The backup vender is recommending the below fix: To troubleshoot the issue please perform the following: - restart following services in this sequence: 1. COM+ Event System. 2. COM+ System Application Service. This may not be started (if not, start it). 3. Distributed Transaction Coordinator Service. 4. Volume Shadow Copy Service. 5. SQL Server VSS Writer. Would restart of any of the above services impact recording of tag data or any of the other main functions of the Historian server?

  • Author: Kevin Modlin
  • Published: March 7th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 03/29/2023
Case: 84093
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand