Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Historian
  • AVEVA Historian Support Cases

[ISS Support Case] A2ALMDB Migration

Last updated: October 17th, 2025

Description

I trying to copy an A2ALMDB database from an existing ASP2020 R2 SP1 system (upgraded from ASP2014 R2 SP1) to a newly installed ASP2020 R2 SP1 system. On the new system alarms are logged as expected to the A2ALMDB database created by the Configurator. However, when I backup the A2ALMDB database from the existing system and restore to the new system, alarms are no longer logged. I'm guessing this is a security/authentication issue. I see one warning in the Historian logger "Please update Historian Server properties with valid credentials (on client computer)". I'm not sure that's the underlying issue and how to do that.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Historian
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 09/14/2022
Case: 82481
Give feedback about this article

Recommended articles

[ISS Support Case] Historian loses connection after shutting down

If the historian is shut down and disabled then re-enabled it doesn't connect to tags that haven't changed. Reboot re-establishes connection.

Read More

[ISS Support Case] Trying to access old history blocks

They have a very old system they're trying to open a trend or see the data, but they don't see a trend program and can't figure out how to open the file. They believe they have the data, but it's running in demo mode and won't show data. This is an offline PC and they want to avoid putting it online, so we can't do a screen share.

Read More

[ISS Support Case] Trend SQL Login Failure

Client reached out due to receiving time out error message when logging into SQL to View Trends remotely on Development node.

Read More

[ISS Support Case] Wanting to pull 9 months of historized data

-Customer is wanting Historized data from the last 9 months in a .CSV file. Or in SQL. and wants to know the best practices.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand