[ISS Support Case] Intermittent Trend

Last updated: October 17th, 2025

Description

The customer reports that trend displays for multiple incubators intermittently stop showing data after a period of operation. Historical data remains present in the MySQL database and can be retrieved manually, indicating that the issue is isolated to the display/trend retrieval process rather than data collection. The problem previously occurred when using the Aveva proprietary trend file format and continues after migrating to MySQL-based storage. When the failure occurs: Trend displays show no data or frozen data. Restarting the Aveva SCADA service or rebooting the PC restores normal operation. Restarting only the MySQL database service does not resolve the issue. Log file analysis shows repeated MySQL errors: Can't create more than max_prepared_stmt_count statements (current value: 16382) This indicates the MySQL server has reached the configured limit for prepared SQL statements. The prepared statement count appears to increase over time without being released, suggesting a resource leak in the trend query handling. Once the limit is reached, all subsequent queries fail until the SCADA service is restarted, which clears the open statements. Impact: Trend displays become non-functional until the SCADA service or PC is restarted. Historical data is unaffected.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Aveva Edge
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 08/22/2025
Case: 98847
Give feedback about this article

Recommended articles

[ISS Support Case] Singular Edge HMI\Node Crashing Issue

Client reached out due to an induvial Edge node crashing within 12 hours of operation repeatedly.

Read More

[ISS Support Case] Edge crashing after printing report

Edge 2023 crashing often when printing reports Viewer module could not connect to the runtime

Read More

[ISS Support Case] External email with attached file in Edge

Client reached out as they were attempting to use the SenEmailExt() function in Edge.

Read More

[ISS Support Case] License Tag Count Error

After completing a new install and licensing the product with no errors the message pops up that the 1.5k tag license cannot license the amount of tags in the application(637) and runs in demo mode

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand