[ISS Support Case] Edge script not executing

Last updated: October 17th, 2025

Description

Customer is working with AVEVA Edge 2023 R2 running on Windows 11 (24H2 build). They recently created a new virtual image and installed this version of Edge. Within their application, they are running a script that is known to work successfully on multiple other machines with the same Edge version. However, on this particular environment, the script fails to execute properly. When the script runs: The manifest import (non-destructive) executes successfully. The destructive import fails and triggers application instability. After failure, the application encounters a hard crash (Edge shuts down completely). Dump files show error messages such as invalid pointer and read bgtas.dll error. Customer has uploaded a dump file for review: [Box link provided]. Steps Taken / Observations Verified that the same script executes successfully on other machines with the same AVEVA Edge version. Issue appears specific to this new virtual image and environment. Dump file analysis points to possible pointer or DLL handling issue during destructive import.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Aveva Edge
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 08/28/2025
Case: 99088
Give feedback about this article

Recommended articles

[ISS Support Case] Singular Edge HMI\Node Crashing Issue

Client reached out due to an induvial Edge node crashing within 12 hours of operation repeatedly.

Read More

[ISS Support Case] Edge crashing after printing report

Edge 2023 crashing often when printing reports Viewer module could not connect to the runtime

Read More

[ISS Support Case] External email with attached file in Edge

Client reached out as they were attempting to use the SenEmailExt() function in Edge.

Read More

[ISS Support Case] License Tag Count Error

After completing a new install and licensing the product with no errors the message pops up that the 1.5k tag license cannot license the amount of tags in the application(637) and runs in demo mode

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand