[ISS Support Case] Edge Project Started Freezing Intermittently

Last updated: October 17th, 2025

Description

Has been working on a project for the past week with no issue and looses access to open properties on objects. Has to shut down the program and restart to recover. Edge doesnt fully lock just looses access to the object properties. Can still access menu items, close screens and open screens. This started in the past week periodically at first and has increased in frequency. Now occurs roughly every 15 minutes or 5-6 actions. Has a base program and customizes to fit a panel Opens an object for instance and clicks to select tag to define object visibility. gets : data synchronization message In previous versions of the project to resolve he would go to Global project tags and update

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Aveva Edge
Version: 2020
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 02/18/2022
Case: 81031
Give feedback about this article

Recommended articles

[ISS Support Case] Singular Edge HMI\Node Crashing Issue

Client reached out due to an induvial Edge node crashing within 12 hours of operation repeatedly.

Read More

[ISS Support Case] Edge crashing after printing report

Edge 2023 crashing often when printing reports Viewer module could not connect to the runtime

Read More

[ISS Support Case] External email with attached file in Edge

Client reached out as they were attempting to use the SenEmailExt() function in Edge.

Read More

[ISS Support Case] License Tag Count Error

After completing a new install and licensing the product with no errors the message pops up that the 1.5k tag license cannot license the amount of tags in the application(637) and runs in demo mode

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand