Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Edge
  • AVEVA Edge Support Cases

[ISS Support Case] Allen Bradley CIP Driver Optimization Inquiry

Last updated: October 17th, 2025

Description

recently updated a project from IndusoftWeb Studio version 8 to IndusoftWeb Studio 2020 R2 with ABCIP drivers 11.24. The application is a client server application before the update there were 8 clients with 8 CompactLogix PLC rev 32 and there were no issues. After the update we added 2 new clients and 2 new PLC to the system the new plc are identical to the other 8 and so the tags. The strange thing is that we are having communication issues with the new clients and PLC, we double check the tags name no errors for invalid tags. Issues I see is sometimes we see ???? for the values one of the screens. We also have a script on a screen, while open script that execute every second writing 6 values (date/time) to the PLC sometimes the month and day dont get updated. I go online with the plc using Studio 5000 I can see the seconds getting update but not the day and month if I write 0 to the tags using Studio 5000 then I see the values getting updated from the HMI. I am looking for recommendations on the best way to optimize the ABCIP drives currently I have just the main driver sheet with a total of 2282 tags for all 10 plcs. What is the recommended for buffer size, simultaneous request maximum and maximum per station, currently they are default values of 1 should I change it to maximum request to and the driver will then establish one thread per station/plc 10 and 1 per station.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Aveva Edge
Version: 2020 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 06/12/2025
Case: 98182
Give feedback about this article

Recommended articles

[ISS Support Case] Singular Edge HMI\Node Crashing Issue

Client reached out due to an induvial Edge node crashing within 12 hours of operation repeatedly.

Read More

[ISS Support Case] Edge crashing after printing report

Edge 2023 crashing often when printing reports Viewer module could not connect to the runtime

Read More

[ISS Support Case] External email with attached file in Edge

Client reached out as they were attempting to use the SenEmailExt() function in Edge.

Read More

[ISS Support Case] License Tag Count Error

After completing a new install and licensing the product with no errors the message pops up that the 1.5k tag license cannot license the amount of tags in the application(637) and runs in demo mode

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2025 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand