Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Batch
  • AVEVA Batch Tech Notes

TN IB005 InBatch .NET Controls

Last updated: March 7th, 2025

Description

  • Author: Brian Schneider
  • Published: March 7th, 2025

Details:

Description

This article from InSource provides a listing of the .NET controls included with Wonderware InBatch software.

  • Author: Rich Brooks
  • Published: 11/17/2016
  • Applies to: InBatch 2014R3 and higher

Details

The .NET controls included with InBatch are frequently embeded in an ArchestrA graphic to provide a programming or user interface. These .NET controls expose their properties, methods, and events when their associated ArchestrA graphic is dropped on a window in InTouch. The .NET controls are installed in InBatch as a part of the InBatch Components for ArchestrA IDE. They do need to be imported into the Integrated Development Environment (IDE). Select Galaxy | Import | Client Controls from the menu of the IDE. Browse to the C:\Program Files (x86)\Wonderware\InBatch\AppObjects folder to select IBGuiControls.Net.dll. Click the Open button.

You will then have access to embed these .NET controls from the symbol editor. 

The controls are added graphically to one or more ArchestrA symbols.

Non-GUI Control

This is invisible at runtime. It has no runtime graphical component. The control relies on scripting to utilize it.

Batch Gui Config Control

The BatchGuiConfig .NET control provides central administration of all Batch GUI controls for an application. A connection to the InBatch server is defined in this control.

GUI Controls

These are visible at runtime. They have a graphical runtime component. The controls rely on the user to interact with it.

InBatch SFC Control

The InBatchSFC .NET control provides a visual representation of a running batch.

Batch List Control

The BatchList .NET control provides live list data. You can configure the BatchList control to be a schedule list, active batch list, active phase list, or parameter list.

Batch Field Control

The BatchField .NET control is a data field that is linked to a BatchList control.

Batch Button Control

The BatchButton .NET control is a configurable batch action button.

You may reference the Wonderware InBatch User's Guide for more details on each of the controls.

NOTE: The InBatch Batch Control and Batch Security Control are only available as ActiveX controls.

inbatch controls .net integration
Give feedback about this article

Recommended articles

TN IB001 Configuring InBatch Remote Development Client

Read More

TN IB001 How to import Recipes into InBatch from an XML file

Read More

TN IB001 How to turn on Security in InBatch 2012 R2

Read More

TN IB002 Create Batch Scheduler in InTouch Using InBatch ActiveX Objects

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand