TN IB001 Configuring InBatch Remote Development Client

Last updated: March 4th, 2025

Description

  • Author: Brian Schneider
  • Published: March 4th, 2025

Details:

Description

This article from InSource show how to configure a remote client PC to run the Remote Development client functions for the Wonderware InBatch product. This would include interactive interfaces like the Process Model, Recipe Editor, Batch Scheduler and so forth. This also applies to custom coding of the InBatch API for the Materials Database and the Recipe Database. 

  • Author: Chris Selph
  • Published: 3/5/2019
  • Applies to: InBatch 2014 R3 and above

Details

Assumptions:

The InBatch Development Client is installed and licensed

On the InBatch Server Computer

Using the Environment Display perform and Exit and shutdown command (this will disable InBatch!)

Run the Wonderware Configurator

Make sure the “Share InBatch for Remote Development Clients” checkbox is checked. Execute Configure

Start Environment Display to restart InBatch
Start applications

On the Client Remote PC

Run the configurator – pick any unused drive letter for Folder Drive Mapping – Do NOT map this drive ahead of time – the configurator will map it for you.

Run the Configure

To Test functions:

Run Material Editor and verify you can see materials. If it doesn’t start check the logger for an error about TAF. If there is a message then delete Vista.TAF from the Config_A folder on the server


If you need to run custom Material or Recipe API automation server commands from this remote client node, do the following:

from command prompt, run DCOM configuration utility:

mmc comexp.msc /32

Edit the DCOM configuration of the material server or recipe server:

Configure each tab as follows:

End of article.

inbatch configuration remote client
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More

How to receive group emails

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand