Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • AVEVA Batch
  • AVEVA Batch Tech Notes

TN IB004 Resetting InBatch Security

Last updated: March 7th, 2025

Description

  • Author: Rich Brooks
  • Published: March 7th, 2025

Details:

Description

This article from InSource shows how to reset the security for Wonderware InBatch. The loss of the administrative login for InBatch will require a reset to the system defaults.

  • Author: Rich Brooks
  • Published: 10/17/2016
  • Applies to: Wonderware InBatch 2012 and higher

Details

It is sometimes necessary to reset the administrative login for InBatch.

A lost password will require resetting the full Security in InBatch to the defaults.

Start by creating a backup of the configuration files located in the C:\Program Files (x86)\Wonderware\InBatch\cfg\Config_A folder.

Copy the three SecurityDB files found in the C:\Program Files (x86)\Wonderware\InBatch\cfg\dflt_cfg folder. These are the default Security configuration files.

Paste the three copied SecurityDB files in the C:\Program Files (x86)\Wonderware\InBatch\cfg\Config_A folder.

Note: All security roles, operator stations, user accounts, and applications-functions configured from the Security Manager will be lost. These settings will need to be added back manually following the reset. 

Select Replace the files in the destination to confirm the paste. You are over writing the configured Security files.

The Environment Display will now open with no prompt for a password. You may log into SecEdit using system as the login and password.

 

inbatch security resetting
Give feedback about this article

Recommended articles

TN IB001 Configuring InBatch Remote Development Client

Read More

TN IB001 How to import Recipes into InBatch from an XML file

Read More

TN IB001 How to turn on Security in InBatch 2012 R2

Read More

TN IB002 Create Batch Scheduler in InTouch Using InBatch ActiveX Objects

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand