[ISS Support Case] Failing to Upgrade Batch Management 2017 (V12.1) To Batch Management 2023 R2 (V13.1)

Last updated: October 17th, 2025

Description

Client reached out as when user was attempting to configure the History Server tab under Batch Management it would fail with the following errors: Component: History Server "ExecutionNonQuery failed for Database "B2BatchHistory" "An exception occurred while executing a Transact-SQL statement or batch." "ExecuteNonQuery failed for Database 'B2BatchHistory'. An exception occurred while executing a Transact-SQL statement or batch. Cannot drop type 'dbo.Text_Chunk_NVARCHAR128' because it is being referenced by object 'EquipStatus'. There may be other objects that reference this type."

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Batch Management
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 05/21/2025
Case: 97862
Give feedback about this article

Recommended articles

[ISS Support Case] InBatch .NET Object Parameter Not Updating Properly

When passing an empty string into BatchGui unit parameter the display fails to initialize with Batch information.

Read More

[ISS Support Case] Batch Server Reporting Configuration Failure

Client reached out as they were receiving the following error when attempting to configure Batch Server Reporting on remote node: "An error occurred during configuration of the reporting d\feature" This error was shown at the same time in the logger: "The request failed with HTTP status 503: Server too Busy"

Read More

[ISS Support Case] Inbatch 2014 r3 issue with reports

Inbatch reports - he clicks on it and the coniguration doesnt open. windows server 2012 r2, inbatch v2014 r3

Read More

[ISS Support Case] InBatch Migration

3/4/2024: -Installed Inbatch system 2014 R2. -Wanting to upgrade to 2023 R2 Batch management. 3/5/2024: -Awaiting word back from L2 about best practices when upgrading InBatch.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand