[ISS Support Case] Alarm Client

Last updated: October 17th, 2025

Description

The alarm client graphic does not display alarms outside of prioriy 1 Tested in active X control client for historical alarms and it works. logs alarms and events in new version 2023 but not in 2017 Issue Summary: Customer reported that the Alarm Client graphic within the InTouch HMI is not displaying alarms outside of Priority 1. The expectation is to see alarms across a broader range of priorities (e.g., 1999), but only Priority 1 alarms are being rendered by the default Alarm Client graphic. Troubleshooting Steps Performed: Script Validation and Elimination: Reviewed and validated all associated scripts for the Alarm Client graphic. Disabled all scripts temporarily to eliminate the possibility of script interference impacting the alarm display. Configuration Review: Verified that all custom properties and connection parameters for the Alarm Client graphic were properly configured and not filtering or restricting alarms by priority. Controlled Test Setup: Created a new test window within InTouch to eliminate legacy or hidden configurations. Added: A default Alarm Client graphic. An ActiveX Alarm Control for comparison. Ensured both controls had the most basic configuration with no script interactions. Behavior Observation: The Alarm Client graphic continued to show only Priority 1 alarms. The ActiveX Alarm Control correctly displayed alarms of various priorities, confirming that the alarm data was available and being delivered correctly from the system. Historian Data Verification: Accessed the SQL database via SQL Server Management Studio (SSMS). Queried the Historian to confirm the presence of alarms across a range of priorities (1999). Verified the accuracy of query syntax using reference documentation and observed that the data exists and is populated correctly. Documentation and Evidence: A screen recording has been created and is available, demonstrating: The tested behavior. Alarm Client configuration settings. Comparison between Alarm Client and ActiveX control. The presence of multi-priority alarms in the Historian.

  • Author: Kevin Modlin
  • Published: October 17th, 2025

Details:

Product: Application Server
Version: 2023 R2
Solution: [Solution is visible below when you're logged in and have a current subscription]
Date Created: 06/03/2025
Case: 97719
Give feedback about this article

Recommended articles

[ISS Support Case] Synchronize Views is not working correctly in the IDE

Read More

[ISS Support Case] Historian Data Gap On Appengine Failover In SP Version 2023 R2 P1

I am seeing an issue with SP2023 R2 P1 related to appengine failovers. When I cause an appengine failover, data (primarily analog) has a gap in the trend until the data changes. Sometimes the gap stays but sometimes the gap is "filled" in for some reason. I'm having a bit of a consistency issue trying to replicate this problem. Every time I cause a failover, the results are slightly different but I do see bad results. To demonstrate this, I created two videos to show what I'm seeing. If someone can create a problem ticket and reach out to me, I can forward the videos to InSource to show what I'm seeing.

Read More

[ISS Support Case] MQTT setup crashes OCMC

MQTT server - CDP 2023 check encryption/validate security - no issue port validates enable user identity/try to bring certs in shuts down OCMC nothing in OCMC logs event viewer shows an app crash for mmc with cfg_mqtt_plctype1.dll as the faulting module advised repair after conferring with aveva - called client to discuss and confirm New SR960455477 (requesting) Log file Config Files Do Not upgrade Stay @ the same version of CDP Call in on 9/12/2024 No success on the MQTT server with the antivirus turned off, and it was even worse this time. Could not hook to AWS server. Proceeded to step 2, entered certificate in case it needed to log in to AWS server, but the OCMC shut down. Restarted OCMC acted strange, restarted computer. OCMC behaved normally after, but still no success with MQTT. Wants a call back whenever you're available, doesn't have to be tonight. CDP shows 2023

Read More

[ISS Support Case] OMI Slow to update Values over OPCUA

Communications pack 2023.1 P02

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand