TN WIS116 How to Manually Delete in WIS Windowset
Last updated: March 23rd, 2026Description
- Author: Brian Schneider
- Published: March 23rd, 2026
Details:
Description
This article from InSource shows How to Manually Delete a Wonderware Information Server Windowset
- Author: Benjamin Davis
- Published: 03/27/2017
- Applies to: Wonderware Information Server
Details
- In Windows Explorer, navigate to C:\inetpub\wwroot\suitevoyager\winroot (Location of published windowsets)
- Open the wwcfg.xml file and note the Windowset to be deleted, and remember the URL attribute value
- Find and delete the URL folder that is referenced in the wwcfg.xml file
- Open the windowset level wwcfg.xml file again in Notepad
- Delete the desired windowset reference from the xml file
- Save and close the file.
- Verify the windowset is deleted from the WIS Portal