TN Appsvr132 Configuring the ArchestrA Reporting in Information Server when SQL Reporting Services is configured with SSL security

Last updated: February 20th, 2025

Description

  • Author: Joe Hefner
  • Published: February 20th, 2025

Details:

Description

Once SQL Reporting Services has been configured with SSL security Wonderware Information Server will be unable to configure the ArchestrA Reporting. This document walks through the necessary steps to remove SSL from SQL Reporting Services.

  • Author: Joseph Hefner
  • Published: 06/04/2015
  • Applies to: Information Server 4.5 and above

Details

This problem can be identified by going into the SMC Log VIewer after the failed configuration of ArchestrA Reporting and looking for the message below:

Configuration failed. 
System.Web.Services.Protocols.SoapException: The operation you are attempting requires a secure connection (HTTPS). Microsoft.ReportingServices.Diagnostics.Utilities.SecureConnectionRequiredException: The operation you are attempting requires a secure connection (HTTPS). 

Once you have confirmed the message above you can proceed to correct this problem by following the instructions below:

Step 1)

Launch the SQL Server Reporting Services Configuration Manager and connect as in the screenshot sbelow:

Step 2)

Navigate to the Web Service URL and click the Advanced button beside the SSL certificate as below:

Step 3)

Remove all entries from the "Multiple SSL Identities" section by clicking the Remove buton as below:

Step 4)

Click the Report Manager URL and then click the Advanced button as below:

Step 5)

Remove all entries from the "Multiple SSL Identities" section by clicking the Remove button as below:

Step 6)

Navigate to the following directory and locate the file "rsreportserver.config"

C:\Program Files\Microsoft SQL Server\MSRS11.MSSQLSERVER\Reporting Services\ReportServer

Step 7) Double click the rsreportserver.config now to open it and search for secureconnectionlevel as below:

 

archestra reporting ssl security
Give feedback about this article

Recommended articles

TN Citect007 How to test that your Wonderware Information Server has HTTP Secure availability

Read More

[ISS Support Case] Looking for WIS 5.6 Installation Media

Direct email: when I try to install Wonderware System Platform R2 SP1 upgrade, I can't continue because the upgrade needs Wonderware Information Server 5.6, but I only have version 5.5. Could you help to provide a download link for Wonderware Information Server 5.6?

Read More

[ISS Support Case] WIS Auto Login

Quick question, how to disable the auto login at client PC? Initially the login pop up but there is optional check box to save the login info. Please let me know.

Read More

[ISS Support Case] Information Server proper upgrade path

Upgrade path to versions beyond 2014 R2.

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand