Some content on this site is available only to logged-in subscribers. Contact Us for information on becoming a subscriber.

InSource.Solutions | InSource Training | InSource Client Portal
InSource Solutions Logo
Log In Sign Up
InSource.Solutions InSource Training InSource Client Portal Log In Sign Up
  • Home
  • Supporting Technologies (i.e. Windows / SQL Server / VMWare / etc.)

TN WW132 How to fix SQL after computer name is changed.

Last updated: February 20th, 2025

Description

  • Author: Ernest Lee
  • Published: February 20th, 2025

Details:

Description

Renaming a Computer that Hosts a Stand-Alone SQL Server Instance

  • Author: Ernest Lee
  • Published: 11/25/2015
  • Applies to: SQL 2008 SP1 and higher

Details

You can connect to SQL Server by using the new computer name after you have restarted SQL Server. To ensure that @@SERVERNAME returns the updated name of the local server instance, you should complete either of the following procedures. The procedure you use depends on whether you are updating a computer that hosts a default or named instance of SQL Server.

Figure 1 (below) shows that the Host name is correct, but running SELECT @@SERVERNAME AS 'Server Name' returns the old server name. The New Server Name should return VMK6432New.

To rename a computer that hosts a stand-alone instance of SQL Server 

Run the following Stored Procedures:

sp_dropserver <old_name>
GO
sp_addserver <new_name>, local
GO

To rename a computer that hosts a named instance of SQL Server,

Run the following Stored Procedures:

sp_dropserver <'old_name\instancename'>
GO
sp_addserver <'new_name\instancename'>, local
GO

Example

To rename a computer that hosts a default instance of SQL Server

Run the following Stored Procedures (Figure 2 below).

sp_dropserver VMK6432New
GO
sp_addserver VMK6432New, local
GO

Restart the SQL Server (MSSQLSERVER) service (Figure 3 below).

As a result of the Host running SELECT @@SERVERNAME AS 'Server Name' statement the current server name is returned (Figure 4 below). 

 

sql fix computer change
Give feedback about this article

Recommended articles

TN - 1240 Creating a Watchlist Using an Import File

Read More
Support Icon

CONTACT SUPPORT

How to reach us

10800 Midlothian Turnpike Tpke, Suite 209, Richmond, VA 23235

1.877.INSOURCE

Technical Support - 1.888.691.3858

Contact Us

  • InSource Solutions
  • InSource Training
  • InSource Client Portal
  • Log In
InSource Solutions Group Logo

© 2026 InSource Solutions. All Rights Reserved.

Knowledge Base Software powered by Helpjuice

Expand